Sheathless electrospray from polymer microchips

被引:55
作者
Svedberg, M
Pettersson, A
Nilsson, S
Bergquist, J
Nyholm, L
Nikolajeff, F
Markides, K
机构
[1] Uppsala Univ, Dept Analyt Chem, S-75124 Uppsala, Sweden
[2] Uppsala Univ, Dept Mat Sci, Angstrom Lab, S-75121 Uppsala, Sweden
关键词
D O I
10.1021/ac030045t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, sheathless electrospray from polymer microchips with conducting layer on the emitter tip is described for the first time. The electrospray emitter tips were fabricated directly from the end of the microchips that were made of polycarbonate or poly(methyl methacrylate) with injection molding. A variety of tip shapes and conducting coatings were evaluated using an electrospray time-of-flight mass spectrometer run in the sheathless mode. Stable electrospray was obtained both from hand-polished and machine-milled three-dimensional tips coated with either polymer-embedded gold particles or graphite particles as the conducting layer. Sputtered gold, on the other hand, suffered from poor stability mainly due to bad adhesion to the polymer tip. The durability of the different coatings was confirmed with electrochemical experiments under simulated electrospray conditions. The relative standard deviations of the response received from the ion current of the MS analysis were in the range of 3.5-12%. The detection limit for a standard mixture containing five neuropeptides was lower than 0.5 fmol. The low detection limit makes the emitter tips highly attractive for the analysis of low-abundance biological species.
引用
收藏
页码:3934 / 3940
页数:7
相关论文
共 45 条
[1]   A design for low-flow sheathless electrospray emitters [J].
Barnidge, DR ;
Nilsson, S ;
Markides, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4115-4118
[2]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[3]  
Chartogne A, 2000, RAPID COMMUN MASS SP, V14, P1269, DOI 10.1002/1097-0231(20000730)14:14<1269::AID-RCM24>3.0.CO
[4]  
2-F
[5]  
Chen SH, 2000, MESA MG, P497
[6]  
Chen SH, 2001, ELECTROPHORESIS, V22, P3972, DOI 10.1002/1522-2683(200110)22:18<3972::AID-ELPS3972>3.0.CO
[7]  
2-6
[8]  
Cole R.B., 1997, Electrospray Ionization Mass Spectrometry
[9]  
FIGEYS D, 1999, J CAPILLARY ELECTROP, V6, P1
[10]   Micromachining in plastics using X-ray lithography for the fabrication of micro-electrophoresis devices [J].
Ford, SM ;
Davies, J ;
Kar, B ;
Qi, SD ;
McWhorter, S ;
Soper, SA ;
Malek, CK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :13-21