Determination of nitroaromatic compounds in air samples at femtogram level using C18 membrane sampling and on-line extraction with LC-MS

被引:54
作者
Sánchez, C
Carlsson, H
Colmsjö, A
Crescenzi, C
Batlle, R
机构
[1] Univ Stockholm, Dept Analyt Chem, S-10691 Stockholm, Sweden
[2] Swedish Def Res Agcy, FOI, Dept Energet Mat, S-14725 Tumba, Sweden
关键词
D O I
10.1021/ac034278w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper explores the use of C-18 solid-phase extraction membranes for sampling very low concentrations of nitroaromatic compounds in the atmosphere. After sampling, analytes trapped in the membrane are desorbed online directly by a chromatographic mobile phase. The analytes are then separated onto a porous graphitic carbon (PGC) HPLC column. Finally, they are analyzed by an LC-MS/MS detector equipped with an atmospheric pressure chemical ionization (APCI) interface. The method was validated by controlled exposure of the membranes to standard gaseous mixtures of 2,4,6-trinitrotoluene (TNT) and 2,4-dinitrotoluene (2,4-DNT). The developed method was fully characterized, and no breakthrough was observed when sampling volumes up to 9.2 m(3.) Analyses of membranes following medium- and long-term storage demonstrated that samples could be stored on the C-18 membranes without degradation or losses. In addition, the results obtained with this technique were compared with those obtained by a gas chromatographic method in which analytes were collected on Tenax TA and thermally desorbed. The developed method allows sampling at flow rates of 15 L/min and has method detection limits in the femtogram/liter range, with a relative standard deviation lower than 10%. An additional advantage of this method is that it separates most of the TNT and DNT isomers, as demonstrated by applying the method to the analysis of headspace over military-grade TNT explosives.
引用
收藏
页码:4639 / 4645
页数:7
相关论文
共 47 条
[1]   On-line and off-line solid-phase extraction with styrene-divinylbenzene-membrane extraction disks for determining pesticides in water by reversed-phase liquid chromatography diode-array detection [J].
Aguilar, C ;
Borrull, F ;
Marce, RM .
JOURNAL OF CHROMATOGRAPHY A, 1996, 754 (1-2) :77-84
[2]  
AKANASHI M, 2000, TOCHIGI KEN HOKEN KA, V5, P91
[3]   Field-deployable sniffer for 2,4-dinitrotoluene detection [J].
Albert, KJ ;
Myrick, ML ;
Brown, SB ;
James, DL ;
Milanovich, FP ;
Walt, DR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) :3193-3200
[4]   Pattern recognition analysis of optical sensor array data to detect nitroaromatic compound vapors [J].
Bakken, GA ;
Kauffman, GW ;
Jurs, PC ;
Albert, KJ ;
Stitzel, SS .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) :1-10
[5]   Trace analysis of explosives in seawater using solid-phase microextraction and gas chromatography ion trap mass spectrometry [J].
Barshick, SA ;
Griest, WH .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :3015-3020
[6]   On-line coupling of supercritical fluid extraction with high-performance liquid chromatography for the determination of explosives in vapour phases [J].
Batlle, R ;
Carlsson, H ;
Holmgren, E ;
Colmsjö, A ;
Crescenzi, C .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :73-82
[7]  
BATLLE R, IN PRESS ANAL CHEM
[8]   USE OF MEMBRANE EXTRACTION DISKS FOR ONLINE TRACE ENRICHMENT OF ORGANIC-COMPOUNDS FROM AQUEOUS SAMPLES [J].
BROUWER, ER ;
LINGEMAN, H ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1990, 29 (9-10) :415-418
[9]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF POLAR POLLUTANTS IN SURFACE-WATER USING MEMBRANE EXTRACTION DISKS FOR ONLINE TRACE ENRICHMENT [J].
BROUWER, ER ;
VANIPEREN, DJ ;
LISKA, I ;
LINGEMAN, H ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 47 (04) :257-266
[10]   Ground penetrating radar and imaging metal detector for antipersonnel mine detection [J].
Bruschini, C ;
Gros, B ;
Guerne, F ;
Piece, PY ;
Carmona, O .
JOURNAL OF APPLIED GEOPHYSICS, 1998, 40 (1-3) :59-71