Performances of a capillary electrophoresis method for the determination of meso-inositol in a tablet formulation

被引:9
作者
Bennani, N [1 ]
Fabre, H [1 ]
机构
[1] Fac Pharm Montpellier, Chim Analyt Lab, F-34060 Montpellier 2, France
关键词
capillary electrophoresis; meso-inositol; D-fructose; tablet formulation; quantification; validation;
D O I
10.1016/S0003-2670(01)00807-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary zone electrophoresis method is reported for the determination of meso-inositol in a tablet formulation. Separation was carried out in a fused-silica capillary 50.2 cm long (40.2 cm effective length) x 50 mum internal diameter at a potential of 15 kV and 60 degreesC using a 50 mM tetraborate buffer. Detection was by W absorbance at 195 nm. An internal standard (D-fructose) was used to increase method precision. Aqueous standard and test solutions of tablets (4 g l(-1)) were hydrodynamically injected at a pressure of 0.0041 MPa for 6 s. Validation tests demonstrated that the method was reliable and rugged for routine use in quality control. Repeatability of relative corrected peak areas meso-inositol/D-fructose was approximately 2% for 10 injections and 10 preparations of test solutions, respectively Inter-day (10 days) and inter-capillary (two different suppliers) precision was 1.7% for the assay. No influence of day or capillary on the assay was found. Advantages of CE for the purpose of this analysis was the short total analysis time (less than 7 min), the rapid set-up of the instrumentation and the low running cost. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 9 条
[1]   Quantitative and selective analysis of lactose by capillary electrophoresis [J].
Altria, K ;
Ennis, K ;
Sadler, R .
CHROMATOGRAPHIA, 1999, 49 (7-8) :406-410
[2]   Separation and direct UV detection of sugars by capillary electrophoresis using chelation of copper(II) [J].
Bazzanella, A ;
Bächmann, K .
JOURNAL OF CHROMATOGRAPHY A, 1998, 799 (1-2) :283-288
[3]   INFLUENCE OF BORATE COMPLEXATION ON THE ELECTROPHORETIC BEHAVIOR OF CARBOHYDRATES IN CAPILLARY ELECTROPHORESIS [J].
HOFFSTETTERKUHN, S ;
PAULUS, A ;
GASSMANN, E ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :1541-1547
[4]  
*MERCK RES LAB, 1996, MERCK IND, P854
[5]  
*OVP, 1999, VIDAL
[6]   Detection of carbohydrates in capillary electrophoresis [J].
Paulus, A ;
Klockow, A .
JOURNAL OF CHROMATOGRAPHY A, 1996, 720 (1-2) :353-376
[7]  
PESCHET JL, 1999, ANN FALSIFICATIONS E, V92, P191
[8]  
SAGARA K, 1979, CHEM PHARM BULL, V27, P800
[9]   QUANTITATIVE-DETERMINATION OF MYOINOSITOL IN PHARMACEUTICAL PREPARATIONS AND ORGANIC EXTRACTS BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY USING FLUORESCENCE [J].
STEPANEK, J .
JOURNAL OF CHROMATOGRAPHY, 1983, 257 (02) :405-410