A second generation of artificial cornea (Biokpro II)

被引:63
作者
Legeais, JM [1 ]
Renard, G [1 ]
机构
[1] Hop Hotel Dieu, Dept Ophthalmol, Paris, France
关键词
keratoprostheses; polymer; cornea; cell colonization; expanded polytetrafluoroethylene;
D O I
10.1016/S0142-9612(98)00069-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The properties of a new second-generation colonizable artificial cornea were evaluated in humans. The prosthesis consisted of a peripheral rim of a translucent microporous fluorocarbon polymer (expanded polytetrafluoroethylene) fused with the polymer of the central optic. The optic was made of medical-grade polydimethylsiloxane coated with polyvinylpyrrolidone. Its refractive power was 42.2 diopters and it measured 7.0 mm in diameter and 0.55 mm in thickness. The geometry of the optic was tested by high-frequency ultrasound and intraocular pressure and distensibility were measured in an artificial chamber. Prostheses were implanted in one eye of 13 humans. The average follow-up was 6 months (range 3-9 months). Most of the eyes (11/13) were clinically stable after a 7 months follow up. Seven patients had visual acuity improvements. Mean corrected final visual acuity was 20/200 (range, 20/30 to light perception). Five anatomical failures occured (two extrusions, two retroprosthetic membranes, one endophthalmitis). The new optical core, junction, and surface properties of the polymers offer many advantages, quicker colonization of the supporting skirt, and an optical core with a geometry similar to that of a normal human cornea. Epithelial cells did not migrate over the interface and optical core. It seems that formation of an epithelium over the artificial device is essential for the long-term stability of the implant. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1517 / 1522
页数:6
相关论文
共 30 条
  • [1] AQUAVELLA JV, 1982, OPHTHALMOLOGY, V89, P655
  • [2] BARBER JC, 1980, INVEST OPHTH VIS SCI, V19, P182
  • [3] KERATOPROSTHESIS - A LONG-TERM REVIEW
    BARNHAM, JJ
    ROPERHALL, MJ
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1983, 67 (07) : 468 - 474
  • [4] Cardona H, 1991, Refract Corneal Surg, V7, P468
  • [5] MUSHROOM TRANSCORNEAL KERATOPROSTHESIS (BOLT AND NUT)
    CARDONA, H
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 68 (04) : 604 - &
  • [7] POLY(2-HYDROXYETHYL METHACRYLATE) SPONGES AS IMPLANT MATERIALS - INVIVO AND INVITRO EVALUATION OF CELLULAR INVASION
    CHIRILA, TV
    CONSTABLE, IJ
    CRAWFORD, GJ
    VIJAYASEKARAN, S
    THOMPSON, DE
    CHEN, YC
    FLETCHER, WA
    GRIFFIN, BJ
    [J]. BIOMATERIALS, 1993, 14 (01) : 26 - 38
  • [8] INTERPENETRATING POLYMER NETWORK (IPN) AS A PERMANENT JOINT BETWEEN THE ELEMENTS OF A NEW-TYPE OF ARTIFICIAL CORNEA
    CHIRILA, TV
    VIJAYASEKARAN, S
    HORNE, R
    CHEN, YC
    DALTON, PD
    CONSTABLE, IJ
    CRAWFORD, GJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (06): : 745 - 753
  • [9] CHOYCE DP, 1973, SURGERY, V44, P23
  • [10] TISSUE INTERACTION WITH HYDROGEL SPONGES IMPLANTED IN THE RABBIT CORNEA
    CRAWFORD, GJ
    CONSTABLE, IJ
    CHIRILA, TV
    VIJAYASEKARAN, S
    THOMPSON, DE
    [J]. CORNEA, 1993, 12 (04) : 348 - 357