Epidural lidocaine decreases sevoflurane requirement for adequate depth of anesthesia as measured by the Bispectral Index® monitor

被引:117
作者
Hodgson, PS
Liu, SS
机构
[1] Virginia Mason Med Ctr, Dept Anesthesiol, Seattle, WA 98111 USA
[2] Univ Washington, Seattle, WA 98195 USA
关键词
D O I
10.1097/00000542-200105000-00018
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Epidural anesthesia potentiates sedative drug effects and decreases minimum alveolar concentration (MAC). The authors hypothesized that epidural anesthesia also decreases the general anesthetic requirements for adequate depth of anesthesia as measured by Bispectral Index (BIS). Methods: After premedication with 0.02 mg/kg midazolam and 1 mug/kg fentanyl, 30 patients aged 20-65 yr were randomized in a double-blinded fashion to receive general anesthesia with either intravenous saline placebo or intravenous lidocaine control (1-mg/kg bolus dose; 25 mug . kg(-1) . min(-1)). A matched group was prospectively assigned o receive epidural Lidocaine (15 ml; 2%) with intravenous saline placebo. All patients received 4 mg/kg thiopental and 1 mg/kg rocuronium for tracheal intubation. After 10 min of a predetermined end-tidal sevoflurane concentration, BIS was measured. The ED50 of sevoflurane for each group was determined by up-down methodology based on BIS less than 50 (MAC(BIS50)). Plasma lidocaine concentrations were measured. Results: The MAC(BIS50) of sevoflurane (0.59% end tidal) was significantly decreased with lidocaine epidural anesthesia compared with general anesthesia alone (0.92%) or with intravenous lidocaine (1 %; P < 0.0001). Plasma lidocaine concentrations in the intravenous lidocaine group (1.9 <mu>g/ml) were similar to those in the epidural lidocaine group (2.0 mug/ml). Conclusions: Epidural anesthesia reduced by 34% the sevoflurane required for adequate depth of anesthesia. This effect was not a result of systemic lidocaine absorbtion, but may have been caused by deafferentation by epidural anesthesia or direct rostral spread of local anesthetic within the cerebrospinal fluid. Lower-than-expected concentrations of volatile agents may be sufficient during combined egidural-general anesthesia.
引用
收藏
页码:799 / 803
页数:5
相关论文
共 20 条
[1]  
BENDAVID B, 1995, ANESTH ANALG, V81, P525, DOI 10.1097/00000539-199509000-00017
[2]   PHYSICAL AND CHEMICAL-PROPERTIES OF DRUG MOLECULES GOVERNING THEIR DIFFUSION THROUGH THE SPINAL MENINGES [J].
BERNARDS, CM ;
HILL, HF .
ANESTHESIOLOGY, 1992, 77 (04) :750-756
[3]  
CASSUTO J, 1985, ANESTH ANALG, V64, P971
[4]  
DIXON WJ, 1967, STAT ENDOCRINOLOGY, P251
[5]   Effects of subarachnoid bupivacaine block on anesthetic requirements for thiopental in rats [J].
Eappen, S ;
Kissin, I .
ANESTHESIOLOGY, 1998, 88 (04) :1036-1042
[6]  
FORBES AR, 1979, ANESTH ANALG, V58, P497
[7]   Sedation depends on the level of sensory block induced by spinal anaesthesia [J].
Gentili, M ;
Huu, PC ;
Enel, D ;
Hollande, J ;
Bonnet, E .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (06) :970-971
[8]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[9]   EFFECT OF AGE ON EXTRADURAL DOSE REQUIREMENT IN THORACIC EXTRADURAL ANESTHESIA [J].
HIRABAYASHI, Y ;
SHIMIZU, R .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (03) :445-446
[10]   Does epidural anesthesia have general anesthetic effects? A prospective, randomized, double-blind, placebo-controlled trial [J].
Hodgson, PS ;
Liu, SS ;
Gras, TW .
ANESTHESIOLOGY, 1999, 91 (06) :1687-1692