A microfluidic shadow imaging system for the study of the nematode Caenorhabditis elegans in space

被引:77
作者
Lange, D [1 ]
Storment, CW
Conley, CA
Kovacs, GTA
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] NASA, Ames Res Ctr, Moffett Field, CA 94035 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2005年 / 107卷 / 02期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
microfluidics; nematode; Caenorhabditis elegans; shadow imaging; video signal processing; space biology;
D O I
10.1016/j.snb.2004.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reports on a miniaturized shadow imaging device for the investigation of the behavioral effects of spaceflight on the nematode Caenorhabditis elegans, a widely used model organism for the experimental study of genetics, development. radiobiology, as well as behavior and aging. Severe volume and power constraints for the design of satellite payloads indicate the need to miniaturize of space biology experiments and measurement systems. To address this issue. an integrated shadow imager has been developed, It consists of a polycarbonate microculture chamber with a volume of 4 mu L that supports cultures of C elegans worms in liquid media. Gas exchange is enabled through a gas-permeable membrane forming the top of the chamber. Shadow images are acquired with it CMOS video camera chip attached to the bottom of the microchamber. Image artifacts due to diffraction at the worm bodies are reduced by decreasing illumination wavelength and object/camera distance. As an alternative to video acquisition, the filtered video Output signal is Used to determine worm activity, yielding a system that allows image acquisition in combination with a low-bandwidth activity Measurement, Using the described system, the activity of C elegans as a function of ambient temperature was measured. The nematodes were found to show an increase in stroke frequency with temperature. Data obtained by manual counting of worm strokes and the video signal showed good correlation. To our knowledge. this is the first demonstration of maintaining and monitoring C elegans in a microfluidic environment. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:904 / 914
页数:11
相关论文
共 24 条
[1]  
ABHYANKAR VV, 2003, MICRO TOTAL ANAL SYS, P17
[2]   Microgravity effects on Drosophila melanogaster behavior and aging. Implications of the IML-2 experiment [J].
Benguria, A ;
Grande, E ;
deJuan, E ;
Ugalde, C ;
Miquel, J ;
Garesse, R ;
Marco, R .
JOURNAL OF BIOTECHNOLOGY, 1996, 47 (2-3) :191-201
[3]  
BERNSTEIN R, 2002, TECH DIGEST MICRO TO, P793
[4]  
BRENNER S, 1974, GENETICS, V77, P71
[5]   BEYOND RATE OF LIVING [J].
ECONOMOS, AC .
GERONTOLOGY, 1981, 27 (05) :258-265
[6]  
ECONOMOS AC, 1982, AGE, V5, P143
[7]   NORMAL AND MUTANT THERMOTAXIS IN NEMATODE CAENORHABDITIS-ELEGANS [J].
HEDGECOCK, EM ;
RUSSELL, RL .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1975, 72 (10) :4061-4065
[8]   Modular microsystem for epithelial cell culture and electrical characterisation [J].
Hediger, S ;
Sayah, A ;
Horisberger, JD ;
Gijs, MAM .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :689-694
[9]   CAENORHABDITIS-ELEGANS - A MODEL SYSTEM FOR SPACE BIOLOGY STUDIES [J].
JOHNSON, TE ;
NELSON, GA .
EXPERIMENTAL GERONTOLOGY, 1991, 26 (2-3) :299-309
[10]   A review of the effects of microgravity and of hypergravity on aging and longevity [J].
Le Bourg, E .
EXPERIMENTAL GERONTOLOGY, 1999, 34 (03) :319-336