A method for inverse dynamic analysis using accelerometry

被引:60
作者
vandenBogert, AJ
Read, L
Nigg, BM
机构
[1] Faculty of Kinesiology, University of Calgary, Calgary, Alta. T2N 1N4
关键词
accelerometry; inverse dynamics; hip joint;
D O I
10.1016/0021-9290(95)00155-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A method was developed to calculate total resultant force and moment on a body segment, in three dimensions, from accelerometer data. The method was applied for an analysis of intersegmental loading at the hip joint during the single support phase of working and running, using four triaxial accelerometers mounted on the upper body. Results were compared to a conventional analysis using simultaneously recorded kinematics and ground reaction forces. The loading patterns obtained by both methods were similar, but the accelerometry method systematically underestimated the intersegmental force and moment at the hip by about 20%. This could be explained by the inertial and gravitational forces originating from the swing leg which were neglected in the analysis. In addition, the accelerometry analysis was not not reliable during the impact phase of running, when the upper body and accelerometers did not behave as a rigid body. For applications where these limitations are acceptable, the accelerometry method has the advantage that it does not require a gait laboratory environment and can be used for field studies with a completely body-mounted recording system. The method does not require differentiation or integration, and therefore provides the possibility of real-time inverse dynamics analysis. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 19 条
[1]   A COMPARISON OF THE ACCURACY OF SEVERAL HIP CENTER LOCATION PREDICTION METHODS [J].
BELL, AL ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (06) :617-621
[2]  
CLAUSER CE, 1969, WEIGHT VOLUME CTR MA, P69
[3]   BIOMECHANICAL INVESTIGATION OF HUMAN HIP [J].
CROWNINSHIELD, RD ;
JOHNSTON, RC ;
ANDREWS, JG ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :75-85
[4]   DISTRIBUTION OF MATHEMATICAL SOFTWARE VIA ELECTRONIC MAIL [J].
DONGARRA, JJ ;
GROSSE, E .
COMMUNICATIONS OF THE ACM, 1987, 30 (05) :403-407
[5]  
GILBERT J A, 1984, Journal of Orthopaedic Research, V2, P281, DOI 10.1002/jor.1100020310
[6]  
HAUG EJ, 1989, COMPUTER AIDED KINEM, V1, P422
[7]   LEG MOTION ANALYSIS DURING GAIT BY MULTIAXIAL ACCELEROMETRY - THEORETICAL FOUNDATIONS AND PRELIMINARY VALIDATIONS [J].
HAYES, WC ;
GRAN, JD ;
NAGURKA, ML ;
FELDMAN, JM ;
OATIS, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :283-289
[8]  
KANE TR, 1974, BIOMECHANICS, V4, P284
[9]   COMBINING POSITION AND ACCELERATION MEASUREMENTS FOR JOINT FORCE ESTIMATION [J].
LADIN, Z ;
GE, W .
JOURNAL OF BIOMECHANICS, 1991, 24 (12) :1173-1187
[10]  
Levenberg K., 1944, Q. Appl. Math., V2, P164, DOI [10.1090/qam/1944-02-02, DOI 10.1090/QAM/10666, 10.1090/QAM/10666]