Long-term results of eyes with penetrating keratoplasty and glaucoma drainage tube implant

被引:93
作者
Kwon, YH
Taylor, JM
Hong, S
Honkanen, RA
Zimmerman, MB
Alward, WLM
Sutphin, JE
机构
[1] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, Iowa City, IA 52242 USA
[2] Univ Iowa Hosp & Clin, Coll Publ Hlth, Dept Biostat, Iowa City, IA 52242 USA
关键词
D O I
10.1016/S0161-6420(00)00496-6
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose: To present long-term results of eyes with penetrating keratoplasty (PK) and glaucoma tube implant. Design: Retrospective, noncomparative, interventional case series. Participants: We retrospectively reviewed medical records of all patients who underwent both PK and glaucoma tube implant (Baerveldt or Ahmed) at the University of Iowa between July of 1988 and December of 1997 (55 eyes). Methods: Success of the tube implant or PK was evaluated using Kaplan-Meier survival analysis. Association of relevant clinical factors with glaucoma or corneal graft outcome was evaluated using log-rank test or Cox proportional hazard regression analysis. The factors evaluated were glaucoma and cornea diagnoses; prior, simultaneous, and subsequent surgeries; type of tube implant; relative timing of surgeries; and postsurgical complications, Main Outcome Measures: Glaucoma outcome was assessed by postoperative intraocular pressure (IOP), number of medications, and need for further glaucoma surgery. Corneal outcome was assessed by graft rejection, failure, and Snellen visual acuity. Surgical procedures before and during the study period, and their complications were evaluated. Results: The mean preoperative intraocular pressure was 29.8 mmHg with an average of 2.9 medications. At last postoperative follow-up, the mean IOP decreased to 14.3 mmHg with 0.7 medication. The tube implant successfully controlled glaucoma in 45 eyes (82%) at 3 years. More severe postsurgical complications were associated with greater glaucoma failure. Graft rejection occurred in 17 eyes, and 7 of these progressed to failure. Nonimmunologic graft failure occurred in an additional 17 eyes (31%). The remaining 31 eyes (56%) had a clear graft. The corneal grafts remained clear in 70% and 55% of eyes at 2 and 3 years, respectively. Corneal graft failure was associated with glaucoma and cornea diagnoses groups, type of tube implant, and relative timing of the two surgeries. Complications occurred in 23 eyes (42%), and 10 of these were serious. Conclusions: A drainage tube implant can successfully control glaucoma in a majority (82%) of keratoplasty eyes at 3 years. However, the success of corneal grafts is low (55%) at 3 years. Postsurgical complications are not uncommon and are associated with poor glaucoma outcome. Other clinical factors are associated with poor graft outcome. Ophthalmology 2001;108:272-278 (C) 2001 by the American Academy of Ophthalmology.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 23 条
[1]
Comparison of mitomycin C trabeculectomy, glaucoma drainage device implantation, and laser neodymium:YAG cyclophotocoagulation in the management of intractable glaucoma after penetrating keratoplasty [J].
Ayyala, RS ;
Pieroth, L ;
Vinals, AF ;
Goldstein, MH ;
Schuman, JS ;
Netland, PA ;
Dreyer, EB ;
Cooper, ML ;
Mattox, C ;
Frangie, JP ;
Wu, HK ;
Zurakowski, D .
OPHTHALMOLOGY, 1998, 105 (08) :1550-1556
[2]
Beebe W E, 1991, Refract Corneal Surg, V7, P67
[3]
BEEBE WE, 1990, OPHTHALMOLOGY, V97, P1414
[4]
CYCLOCRYOTHERAPY FOR GLAUCOMA AFTER PENETRATING KERATOPLASTY [J].
BINDER, PS ;
ABEL, R ;
KAUFMAN, HE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1975, 79 (03) :489-492
[5]
The effect of aspirin on the visual outcome of nonarteritic anterior ischemic optic neuropathy [J].
Botelho, PJ ;
Johnson, LN ;
Arnold, AC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 121 (04) :450-451
[6]
Clinical experience with the Ahmed glaucoma valve implant in eyes with prior or concurrent penetrating keratoplasties [J].
Coleman, AL ;
Mondino, BJ ;
Wilson, MR ;
Casey, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (01) :54-61
[7]
Doyle J W, 1994, Semin Ophthalmol, V9, P254, DOI 10.3109/08820539409060024
[8]
FOULKS GN, 1987, OPHTHALMOLOGY, V94, P871
[9]
GILVARRY A M E, 1989, Eye (London), V3, P713
[10]
THE USE OF SILICONE DRAINAGE TUBING TO CONTROL POST-KERATOPLASTY GLAUCOMA [J].
KIRKNESS, CM ;
LING, Y ;
RICE, NSC .
EYE, 1988, 2 :583-590