Force field particle filter, combining ultrasound standing waves and laminar flow

被引:168
作者
Hawkes, JJ [1 ]
Coakley, WT [1 ]
机构
[1] Univ Wales Coll Cardiff, Sch Biosci, Cardiff CF10 3TL, S Glam, Wales
基金
英国生物技术与生命科学研究理事会;
关键词
ultrasound; standing wave; filter; microfluidic;
D O I
10.1016/S0925-4005(01)00553-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous Row microparticle filter that combines megahertz frequency ultrasonic standing waves and laminar flow is described. The filter has a 0.25 mm, single half wavelength, acoustic pathlength at right angles to the Row. Standing wave radiation pressure on suspended particles drives them towards the centre of the acoustic pathlength. Clarified suspending phase from the region closest to the filter wall is drawn away through a downstream outlet. Experimental tests achieved > 1000-fold clearance of 5 mum yeast cells, at a sample flow rate of 6 mi min(-1), from which the clarified aliquot is 1 mi min(-1). At this flow rate the average residence time in the sound field was <1 s. Latex particles of 25, 9, 5.7, 2.8 and 1.5 mum diameter were also tested. The temperature increase during an operating period > 1h was less than 1 K. The design criteria considered in the fabrication of this high performance device are discussed. A theoretical model of the filter's efficiency, which considers the action of primary radiation force and the particle distribution across a laminar flow profile is presented here. The model predicts that totally clarified filtrate (i.e. zero suspended particles) may be drawn from the downstream outlet. The system described offers a generic approach to automated filtration in some applications. It is continuous Row thereby solving many of the problems of automation presented by batch filter methods and centrifuges. It could be developed for both larger scale and microfluidic applications. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 34 条
[1]  
APFEL RE, 1990, FORTSCH AKUST DAGA 9, P19
[2]  
ARCHER GP, 1993, MICROBIOS, V76, P237
[3]  
BARGER JE, 1964, 57 AC RES LAB HARV U
[4]  
BLITZ J, 1967, FUNDAMENTALS ULTRASO, P27
[5]  
BRODEUR PH, 1994, IEEE ULTR S, P1359
[6]  
COULSON JM, 1977, CHEM ENG, P58
[7]   Dielectrophoretic forces can be safely used to retain viable cells in perfusion cultures of animal cells [J].
Docoslis, A ;
Kalogerakis, N ;
Behie, LA .
CYTOTECHNOLOGY, 1999, 30 (1-3) :133-142
[8]   Dynamic DNA hybridization on a chip using paramagnetic beads [J].
Fan, ZH ;
Mangru, S ;
Granzow, R ;
Heaney, P ;
Ho, W ;
Dong, QP ;
Kumar, R .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4851-4859
[9]   UPPER SOUND PRESSURE LIMITS ON PARTICLE CONCENTRATION IN FIELDS OF ULTRASONIC STANDING-WAVE AT MEGAHERTZ FREQUENCIES [J].
GOULD, RK ;
COAKLEY, WT ;
GRUNDY, MA .
ULTRASONICS, 1992, 30 (04) :239-244
[10]  
GOULD RK, P 1973 S FIN AMPL WA, P252