Dose response of inhaled dry powder insulin and dose equivalence subcutaneous insulin lispro

被引:58
作者
Rave, KM
Nosek, L
De La Peña, A
Seger, M
Ernest, CS
Heinemann, L
Batycky, RP
Muchmore, DB
机构
[1] Profil Inst Stoffwechselforsch, D-41460 Neuss, Germany
[2] Eli Lilly & Co, Indianapolis, IN 46285 USA
[3] Alkermes, Cambridge, MA USA
关键词
D O I
10.2337/diacare.28.10.2400
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To determine the pharmacokinetic (PK) and glucodynamic (GD) dose response of human insulin inhalation powder (HIIP) delivered via AIR particle technology and dose equivalence to subcutaneous (SC) insulin lispro. RESEARCH DESIGN AND METHODS - Twenty healthy, nonsmoking, male or female subjects (aged 29.6 +/- 6.9 years, BMI 23.2 +/- 2.3 kg/m(2), means - +/- SD) with normal forced vital capacity and forced expiratory volume were enrolled in an open-label, randomized, seven-period, euglycemic glucose clamp, cross-over trial. Each subject received up to four single doses of HIIP (2.6, 3.6, 5.2, or 7.8 mg) and three doses of SC lispro (6, 12, or 18 units) from 5 to 18 days apart. RESULTS - HIIP demonstrated a similar rapid onset but an extended time exposure and a prolonged duration of effect (late t(50%) 412 vs. 236 min, P < 0.001) compared with SC lispro. The HIM versus SC lispro doses of 2.6 mg vs. 6 units, 5.2 mg vs. 12 units, and 7.8 mg vs. 18 units achieved similar PK area under the serum immunoreactive insulin (IRI) concentration-versus time curve from time zero until the serum IRI concentrations returned to the predose baseline value [AUC((O-t'))] and GD (G(tot)) responses. The median insulin (t(max)) was not different between HIIP and SC lispro (45 min for both), although the median time of return to baseline for PK was apparently longer for HIIP compared with SC lispro (480 vs. 360 min). Relative bioavailability and relative biopotency of HIIP were consistent across doses (8 and 9%). CONCLUSIONS - While the time-action profile was longer for HIIP than for SC lispro, both treatments showed rapid initial absorption and similar overall PK exposure and GD effect. HIIP was as well tolerated as SC lispro, thereby offering a promising alternative to injectable insulin therapy.
引用
收藏
页码:2400 / 2405
页数:6
相关论文
共 30 条
[1]  
[Anonymous], [No title captured]
[2]  
BINDRA S, 2002, CURR OP ENDOCR DIABE, V9, P338
[3]  
Boss AH, 2005, DIABETES, V54, pA88
[4]  
Bott S, 2000, DIABETOLOGIA, V43, pA46
[5]   Concept, strategies, and feasibility of noninvasive insulin delivery [J].
Cefalu, WT .
DIABETES CARE, 2004, 27 (01) :239-246
[6]   Inhaled human insulin treatment in patients with type 2 diabetes mellitus [J].
Cefalu, WT ;
Skyler, JS ;
Kourides, IA ;
Landschulz, WH ;
Balagtas, CC ;
Cheng, SL ;
Gelfand, RA .
ANNALS OF INTERNAL MEDICINE, 2001, 134 (03) :203-207
[7]  
DEFRONZO RA, 1979, AM J PHYSIOL, V237, pE214
[8]   In vitro and in vivo dose delivery characteristics of large porous particles for inhalation [J].
Dunbar, C ;
Scheuch, G ;
Sommerer, K ;
DeLong, M ;
Verma, A ;
Batycky, R .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 245 (1-2) :179-189
[9]   Large porous particles for pulmonary drug delivery [J].
Edwards, DA ;
Hanes, J ;
Caponetti, G ;
Hrkach, J ;
BenJebria, A ;
Eskew, ML ;
Mintzes, J ;
Deaver, D ;
Lotan, N ;
Langer, R .
SCIENCE, 1997, 276 (5320) :1868-1871
[10]  
Finney D, 1978, STATISTICAL METHOD B, P69