Background. Arterio-venous (a-v) fistulae of haemodialysis patients frequently require function assessment by angiography. The purpose of the present study was to determine the efficacy and safety of ultrasound-guided transbrachial catheterization when a-v fistulae were evaluated. Methods. Between July 1996 and December 1997, 208 dialysis patients, whose a-v fistulae (arterial inflow < 50 ml/min or venous pressure > 150 mm Hg in three consecutive HD sessions) were at the wrist or elbow, underwent transbrachial angiography using an ultrasound-guided 20-gauge IA needle to evaluate fistula function. Procedure-related symptoms or complications were noted in 28 patients and these were analysed. Results. No apparent cases of vessel spasm or thrombosis were noted. Reported symptoms in 28 patients (13.5%) included local arm pain (3.3%), transient paresthesia (0.9%), mild ecchymosis (10.6%) and haematoma (0.9%). All complications were minor and none required surgical intervention. Conclusion. Ultrasound-guided puncture of the brachial artery is a safe, reliable and effective procedure in skilled hands and should be the preferred means of catheterization whenever haemodialysis angiography is performed.
引用
收藏
页码:98 / 101
页数:4
相关论文
共 10 条
[1]  
ANDERSON CB, 1978, ANN SURG, V187, P198
[2]  
BRESCIA JM, 1996, NEW ENGL J MED, V75, P1089
[3]  
BUCKER A, 1995, NEPHROL DIAL TRANSPL, V10, P838
[4]  
ENRIQUE MB, 1986, NEPHRON, V44, P85
[5]   USE OF THE FISTULA ASSESSMENT MONITOR TO DETECT STENOSES IN ACCESS FISTULAS [J].
GANI, JS ;
FOWLER, PR ;
STEINBERG, AW ;
WLODARCZYK, JH ;
NANRA, RS ;
HIBBERD, AD .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1991, 17 (03) :303-306
[6]   COMPLICATIONS OF OUTPATIENT TRANSBRACHIAL INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY - WORK IN PROGRESS [J].
GRITTER, KJ ;
LAIDLAW, WW ;
PETERSON, NT .
RADIOLOGY, 1987, 162 (01) :125-127
[7]  
LOUIS A, 1975, RADIOLOGY, V115, P555
[8]  
MORTIN ME, 1989, RADIOLOGY, V171, P868
[9]  
PAGANO D, 1994, NEPHROL DIAL TRANSPL, V9, P277
[10]   VASCULAR ACCESS FOR HEMODIALYSIS - PATENCY RATES AND RESULTS OF REVISION [J].
PALDER, SB ;
KIRKMAN, RL ;
WHITTEMORE, AD ;
HAKIM, RM ;
LAZARUS, JM ;
TILNEY, NL .
ANNALS OF SURGERY, 1985, 202 (02) :235-239