Clinical consequences of stress shielding after porous-coated total hip arthroplasty

被引:146
作者
Engh, CA [1 ]
Young, AM [1 ]
Engh, CA [1 ]
Hopper, RH [1 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22307 USA
关键词
D O I
10.1097/01.blo.0000096825.67494.e3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
From a series of 223 extensively porous-coated total hip arthroplasties, 208 hips had radiographic followup at a minimum of 2 years, which could be evaluated for radiographic evidence of stress-shielding. These patients had a mean 13.9-year followup (range, 2-18 years). We compared the outcome of 48 total hip arthroplasties that had radiographically evident stress-shielding with 160 total hip arthroplasties that did not have radiographically visible stress-shielding or that had less severe stress-shielding. Stress-shielding was more likely in females, patients with a low cortical index, and patients with larger stems. At the most recent followup, patients with stress-shielding had a lower mean walking score than patients without stress-shielding and less osteolysis. No patients with stress-shielding had femoral loosening, implant fractures, or loss of porous coating. The revision rate was 13% (six hips) among hips with stress-shielding and 21% (33 hips) among hips without stress-shielding. Fifteen-year survivorship was 93% among hips with stress-shielding and 77% among hips without stress-shielding. Stress-shielding did not produce adverse consequences in these extensively porous-coated total hip arthroplasties.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 18 条
[1]
Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement [J].
Bugbee, WD ;
Culpepper, WJ ;
Engh, CA ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1007-1012
[2]
ENGH CA, 1992, CLIN ORTHOP RELAT R, P13
[3]
A QUANTITATIVE-EVALUATION OF PERIPROSTHETIC BONE-REMODELING AFTER CEMENTLESS TOTAL HIP-ARTHROPLASTY [J].
ENGH, CA ;
MCGOVERN, TF ;
BOBYN, JD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1009-1020
[4]
Engh CA, 2001, CLIN ORTHOP RELAT R, P137
[5]
EVALUATION OF BONE INGROWTH IN PROXIMALLY AND EXTENSIVELY POROUS-COATED ANATOMIC MEDULLARY LOCKING PROSTHESES RETRIEVED AT AUTOPSY [J].
ENGH, CA ;
HOOTEN, JP ;
ZETTLSCHAFFER, KF ;
GHAFFARPOUR, M ;
MCGOVERN, TF ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (06) :903-910
[6]
Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty [J].
Engh, CA ;
Culpepper, WJ ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (02) :177-184
[7]
ENGH CA, 1988, CLIN ORTHOP RELAT R, P7
[8]
ENGH CA, 1985, BIOL FIXATION TOTAL, P43
[9]
HARRIS WH, 1992, CLIN ORTHOP RELAT R, P120
[10]
HUISKES R, 1995, CLIN ORTHOP RELAT R, P64