Dialock: a new vascular access device for extracorporeal renal replacement therapy. Preliminary clinical results

被引:35
作者
Canaud, B
My, H
Morena, M
Lamy-Lacavalerie, B
Leray-Moragues, H
Bosc, JY
Flavier, JL
Chomel, PY
Polaschegg, HD
Prosl, FR
Mcgerman, J
机构
[1] St Joseph Hosp, Lyon, France
[2] Lapeyronie Univ Hosp, Dept Nephrol, AIDER, F-34295 Montpellier, France
[3] Biolink Corp, Middleboro, MA USA
关键词
end-stage renal failure; haemodialysis; implantable chamber; permanent catheter; vascular access;
D O I
10.1093/ndt/14.3.692
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Vascular access, a vital tool for end-stage renal disease patients, remains a weak component of extracorporeal renal replacement therapy (RRT) and the first cause of morbidity. Permanent catheters proposed as an alternative to permanent AV fistulae are associated with a significant risk of infection. A subcutaneously implantable chamber connected to permanent catheter appears highly desirable to reduce such hazards. Methods, Dialock(R), a metallic port-like valve device connected to permanent silicone twin catheters has been developed (Biolink Corp, Middleboro, MA, USA). After being implanted subcutaneously below the clavicle, Dialock provides a linear now passage to two Silastic catheters placed in the right atrium via the right internal jugular vein. The valve is accessed percutaneously each dialysis session with needle cannulae that functionally convert the device into twin catheters. Interdialytic patency of the catheters is ensured by antithrombotic lock (heparin or low-molecular-weight heparin). Results. Dialock was implanted in 10 ESRD patients (64+/-12 years) under general anaesthesia, with almost immediate use for I-ID. RRT consisted of three IID sessions per week lasting 4 h; 699 HD sessions were performed. Average duration of use was 5.7 patient-months (1.3-9.6 months). Patient satisfaction was evident in all cases. Three episodes of bacteraemia occurring in the early phase of the study were cured by appropriate antibiotics. No device was removed because of infection. Skin condition at the puncture sites has remained satisfactory in all patients. Nurse training for cannulating was brief (2-3 x). Effective blood now was 307+/- 3.3 mi/min, with a venous pressure of 195+/-39mmHg and a recirculation rate of 6.7 +/- 0.8%. Effective Kt/V dp delivered was 1.36 +/- 0.03 with a nPCR of 1.20+/-0.005g/kg/day. Haematoma and a small amount of bleeding of the skin puncture sites observed in the initial period of the study were effectively prevented by reducing heparin lock volume. Conclusions. The Dialock device offers a new and interesting vascular access alternative for haemodialysis bridging the 'gap' between permanent catheters and arteriovenous fistulae. Dialock's place in the vascular access strategy for haemodialysis patients deserves further long-term clinical studies.
引用
收藏
页码:692 / 698
页数:7
相关论文
共 26 条
[1]   Experience using the Quinton Permcath for haemodialysis in the Irish Republic [J].
Boyle, MJ ;
Gawley, WF ;
Hickey, DP ;
Drumm, J ;
Murphy, DM ;
Hanson, JS ;
Glacken, P .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1997, 12 (09) :1934-1939
[2]  
BRINCKER H, 1986, CANCER, V57, P1124, DOI 10.1002/1097-0142(19860315)57:6<1124::AID-CNCR2820570611>3.0.CO
[3]  
2-D
[4]  
Butler Charles E., 1996, P293, DOI 10.1007/978-0-585-36947-1_11
[5]   INTERNAL JUGULAR-VEIN CANNULATION WITH 2 SILICONE-RUBBER CATHETERS - A NEW AND SAFE TEMPORARY VASCULAR ACCESS FOR HEMODIALYSIS - 30 MONTHS EXPERIENCE [J].
CANAUD, B ;
BERAUD, JJ ;
JOYEUX, H ;
MION, C .
ARTIFICIAL ORGANS, 1986, 10 (05) :397-403
[6]  
Canaud B, 1996, SEMIN DIALYSIS, V9, P397
[7]   A PROSPECTIVE-STUDY OF THE MECHANISMS OF INFECTION ASSOCIATED WITH HEMODIALYSIS CATHETERS [J].
CHEESBROUGH, JS ;
FINCH, RG ;
BURDEN, RP .
JOURNAL OF INFECTIOUS DISEASES, 1986, 154 (04) :579-596
[8]   FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS [J].
DEMEESTER, J ;
VANHOLDER, R ;
DEROOSE, J ;
RINGOIR, S .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1994, 9 (06) :678-683
[9]  
Feldman HI, 1996, J AM SOC NEPHROL, V7, P523
[10]   HEMODIALYSIS VASCULAR ACCESS MORBIDITY IN THE UNITED-STATES [J].
FELDMAN, HI ;
HELD, PJ ;
HUTCHINSON, JT ;
STOIBER, E ;
HARTIGAN, MF ;
BERLIN, JA .
KIDNEY INTERNATIONAL, 1993, 43 (05) :1091-1096