Two-dimensional gas chromatography and trilinear partial least squares for the quantitative analysis of aromatic and naphthene content in naphtha

被引:77
作者
Prazen, BJ
Johnson, KJ
Weber, A
Synovec, RE
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
[2] Dow Chem Co USA, Freeport, TX 77541 USA
关键词
D O I
10.1021/ac010637g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative analysis of naphtha samples is demonstrated using comprehensive two-dimensional gas chromatography (GC x GC) and chemometrics. This work is aimed at providing a GC system for the quantitative and qualitative analysis of complex process streams for process monitoring and control. The high-speed GC x GC analysis of naphtha is accomplished through short GC columns, high carrier gas velocities, and partial chromatographic peak resolution followed by multivariate quantitative analysis. Six min GC x GC separations are analyzed with trilinear partial least squares (tri-PLS) to predict the aromatic and naphthene (cycloalkanes) content of naphtha samples. The 6-min GC x GC separation time is over 16 times faster than a single-GC-column standard method in which a single-column separation resolves the aromatic and naphthene compounds in naphtha and predicts the aromatic and naphthene percent concentrations through addition of the resolved signals. Acceptable quantitative precision is provided by GC x GC/tri-PLS.
引用
收藏
页码:5677 / 5682
页数:6
相关论文
共 40 条
[1]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[2]  
Beens J, 2000, HRC-J HIGH RES CHROM, V23, P182
[3]  
BERTSCH W, 1990, MULTIDIMENSIONAL CHR, P74
[4]  
Blomberg J, 1997, HRC-J HIGH RES CHROM, V20, P539
[5]   Enzymatic browning of vegetables. Calibration and analysis of variance by multiway methods [J].
Bro, R ;
Heimdal, H .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 34 (01) :85-102
[6]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO
[7]  
2-3
[8]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[9]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[10]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984