Analysis of the Air Flow Generated by an Air-Assisted Sprayer Equipped with Two Axial Fans Using a 3D Sonic Anemometer

被引:36
作者
Javier Garcia-Ramos, F. [1 ]
Vidal, Mariano [1 ]
Bone, Antonio [1 ]
Malon, Hugo [1 ]
Aguirre, Javier [1 ]
机构
[1] Univ Zaragoza, Super Polytech Sch, Huesca 22071, Spain
来源
SENSORS | 2012年 / 12卷 / 06期
关键词
sonic anemometer; 3D anemometer; sprayer; fan; air flow; air velocity; SIZED APPLE-TREES; ORCHARD SPRAYER; DEPOSITS; LOSSES; PENETRATION; SPEED; DRIFT;
D O I
10.3390/s120607598
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The flow of air generated by a new design of air assisted sprayer equipped with two axial fans of reversed rotation was analyzed. For this goal, a 3D sonic anemometer has been used (accuracy: 1.5%; measurement range: 0 to 45 m/s). The study was divided into a static test and a dynamic test. During the static test, the air velocity in the working vicinity of the sprayer was measured considering the following machine configurations: (1) one activated fan regulated at three air flows (machine working as a traditional sprayer); (2) two activated fans regulated at three air flows for each fan. In the static test 72 measurement points were considered. The location of the measurement points was as follow: left and right sides of the sprayer; three sections of measurement (A, B and C); three measurement distances from the shaft of the machine (1.5 m, 2.5 m and 3.5 m); and four measurement heights (1 m, 2 m, 3 m and 4 m). The static test results have shown significant differences in the module and the vertical angle of the air velocity vector in function of the regulations of the sprayer. In the dynamic test, the air velocity was measured at 2.5 m from the axis of the sprayer considering four measurement heights (1 m, 2 m, 3 m and 4 m). In this test, the sprayer regulations were: one or two activated fans; one air flow for each fan; forward speed of 2.8 km/h. The use of one fan (back) or two fans (back and front) produced significant differences on the duration of the presence of wind in the measurement point and on the direction of the air velocity vector. The module of the air velocity vector was not affected by the number of activated fans.
引用
收藏
页码:7598 / 7613
页数:16
相关论文
共 17 条
[1]  
[Anonymous], 2000, 98982000 ISO
[2]   Spray deposits and losses in different sized apple trees from an axial fan orchard sprayer: 3. Effects of air volumetric flow rate [J].
Cross, JV ;
Walklate, PJ ;
Murray, RA ;
Richardson, GM .
CROP PROTECTION, 2003, 22 (02) :381-394
[3]   Spray deposits and losses in different sized apple trees from an axial fan orchard sprayer: 1. Effects of spray liquid flow rate [J].
Cross, JV ;
Walklate, PJ ;
Murray, RA ;
Richardson, GM .
CROP PROTECTION, 2001, 20 (01) :13-30
[4]   Spray deposits and losses in different sized apple trees from an axial fan orchard sprayer: 2. Effects of spray quality [J].
Cross, JV ;
Walklate, PJ ;
Murray, RA ;
Richardson, GM .
CROP PROTECTION, 2001, 20 (04) :333-343
[5]   Modelling and validation of the air flow generated by a cross flow air sprayer as affected by travel speed and fan speed [J].
Delele, MA ;
De Moor, A ;
Sonck, B ;
Ramon, H ;
Nicolaï, BM ;
Verboven, P .
BIOSYSTEMS ENGINEERING, 2005, 92 (02) :165-174
[6]  
Derksen RC, 2007, T ASABE, V50, P1493, DOI 10.13031/2013.23941
[7]   Modelling pesticide flow and deposition from air-assisted orchard spraying in orchards: A new integrated CFD approach [J].
Endalew, A. Melese ;
Debaer, C. ;
Rutten, N. ;
Vercammen, J. ;
Delele, M. A. ;
Ramon, H. ;
Nicolai, B. M. ;
Verboven, P. .
AGRICULTURAL AND FOREST METEOROLOGY, 2010, 150 (10) :1383-1392
[8]  
Farooq M, 2002, T ASAE, V45, P1287, DOI 10.13031/2013.11057
[9]  
Garcia-Ramos FJ, 2009, APPL ENG AGRIC, V25, P481
[10]  
Gil Y., 2005, P FRUTIC 05 7 ED FRU, P661