Modelling the input-output behaviour of piezoelectric structural health monitoring systems for composite plates

被引:19
作者
Liu, TR
Veidt, M [1 ]
Kitipornchai, S
机构
[1] Univ Queensland, Dept Mech Engn, Brisbane, Qld 4072, Australia
[2] Univ Queensland, Dept Civil Engn, Brisbane, Qld 4072, Australia
[3] City Univ Hong Kong, Dept Bldg & Construct, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1088/0964-1726/12/5/021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.
引用
收藏
页码:836 / 844
页数:9
相关论文
共 17 条
[1]  
Cawley P, 1997, STRUCTURAL HEALT H MONITORING, P529
[2]   Lamb wave scattering analysis for reflector characterization [J].
Cho, YH ;
Hongerholt, DD ;
Rose, JL .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :44-52
[3]   Ultrasonic waves and material and defect characterization in composite plates [J].
Datta, SK ;
Shah, AH ;
Karunasena, W .
MECHANICS OF COMPOSITE MATERIALS AND STRUCTURES, 1999, 6 (04) :285-300
[4]  
HONGERHOLT D, 1996, IEEE T ULTRASON FERR, V44, P44
[5]   Analysis of acousto-ultrasonic characteristics for contact-type transducers coupled to an orthotropic composite plate [J].
Liu, T ;
Kitipornchai, S ;
Liew, KM ;
Wang, G .
JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 1999, 121 (04) :460-467
[6]   Analysis of acousto-ultrasonic characteristics for contact-type transducers coupled to composite laminated plates [J].
Liu, T ;
Kitipornchai, S ;
Veidt, M .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2001, 43 (06) :1441-1456
[7]   Source influence parameters on elastic guided waves in an orthotropic plate [J].
Pelts, SP ;
Rose, JL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (04) :2124-2129
[8]  
Ristic Velimir M., 1983, PRINCIPLES ACOUSTIC
[9]  
Rose J. L., 1994, Journal of Acoustic Emission, V12, P23
[10]  
Rose J. L., 1995, IEEE ULTR S, P761