Validation of a software designed for computed tomographic (CT) measurement of lung water

被引:28
作者
Malbouisson, LM
Préteux, F
Puybasset, L
Grenier, P
Coriat, P
Rouby, JJ
机构
[1] Univ Paris 06, Hop La Pitie Salpetriere, Dept Anesthesie Reanimat, F-75013 Paris, France
[2] Univ Paris 06, INSERM, U494,Dept Radiol, Hop La Pitie Salpetriere, F-75013 Paris, France
[3] Inst Natl Telecommun, F-91011 Evry, France
关键词
acute respiratory distress syndrome; computed tomography; lung edema;
D O I
10.1007/s001340100860
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective:The in-vitro validation of a computed tomographic (CT) software specifically designed for quantifying the volume of water contained in the lung. Design: An in-vitro, ex-vivo study. In 1993, a postmortem left pneumonectomy was performed in a patient who died from acute respiratory distress syndrome. The lung was fixed, inflated and dried according to a technique proposed by Markarian and Dailey in 1975 aimed at producing a lung specimen spongy in texture and suitable for radiography. Measurements and results: In 1999, 13 CT scans of this lung specimen were performed corresponding to different bronchial instillations of known volumes of water and albumin 4%. The different lung weights resulting from the successive bronchial instillations were calculated using a specially designed software, Lungview, adapted for CT measurements and compared with the actual lung weight measured by an electronic scale. The increase in lung weight measured by Lungview was closely correlated with the actual increase in lung weight resulting from bronchial instillation of water and albumin (y = 0.99x - 23, r = 1 for water and y = x - 17, r = 1 for albumin 4%) and the precision of the bias was 7 g for water and 3 g for albumin 4%. Conclusions: This study shows that the CT software Lungview accurately measured the volume of lung water present within an air-dried exsanguine human lung.
引用
收藏
页码:602 / 608
页数:7
相关论文
共 22 条
[1]   HIGH-RESOLUTION CT OF PARENCHYMAL LUNG-DISEASE - PRECISE CORRELATION WITH HISTOLOGIC-FINDINGS [J].
BESSIS, L ;
CALLARD, P ;
GOTHEIL, C ;
BIAGGI, A ;
GRENIER, P .
RADIOGRAPHICS, 1992, 12 (01) :45-58
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   VOLUME DETERMINATIONS USING COMPUTED-TOMOGRAPHY [J].
BREIMAN, RS ;
BECK, JW ;
KOROBKIN, M ;
GLENNY, R ;
AKWARI, OE ;
HEASTON, DK ;
MOORE, AV ;
RAM, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :329-333
[4]   ESTIMATION OF REGIONAL GAS AND TISSUE VOLUMES OF THE LUNG IN SUPINE MAN USING COMPUTED-TOMOGRAPHY [J].
DENISON, DM ;
MORGAN, MDL ;
MILLAR, AB .
THORAX, 1986, 41 (08) :620-628
[5]   Computed tomography and pulmonary measurements [J].
Drummond, GB .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (05) :665-671
[6]  
FORSTER BB, 1982, JPN HEART J, V23, P697
[7]   PULMONARY-EDEMA - A CT STUDY OF REGIONAL CHANGES IN LUNG DENSITY FOLLOWING OLEIC-ACID INJURY [J].
HEDLUND, LW ;
EFFMANN, EL ;
BATES, WM ;
BECK, JW ;
GOULDING, PL ;
PUTMAN, CE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (05) :939-946
[8]   HYDROSTATIC PULMONARY-EDEMA - AN ANALYSIS OF LUNG DENSITY CHANGES BY COMPUTED-TOMOGRAPHY [J].
HEDLUND, LW ;
VOCK, P ;
EFFMANN, EL ;
LISCHKO, MM ;
PUTMAN, CE .
INVESTIGATIVE RADIOLOGY, 1984, 19 (04) :254-262
[9]   SCANNER CONFORMITY IN CT DENSITOMETRY OF THE LUNGS [J].
KEMERINK, GJ ;
LAMERS, RJS ;
THELISSEN, GRP ;
VANENGELSHOVEN, JMA .
RADIOLOGY, 1995, 197 (03) :749-752
[10]   THE UNRELIABILITY OF CT-NUMBERS AS ABSOLUTE VALUES [J].
LEVI, C ;
GRAY, JE ;
MCCULLOUGH, EC ;
HATTERY, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (03) :443-447