Untreated lung cancer: Quantification of systematic distortion of tumor size and shape on non-attenuation-corrected 2-[fluorine-18]fluoro-2-deoxy-D-glucose PET scans

被引:22
作者
Zasadny, KR
Kison, PV
Quint, LE
Wahl, RL
机构
[1] UNIV MICHIGAN,MED CTR,DEPT INTERNAL MED,DIV NUCL MED,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,MED CTR,DEPT RADIOL,ANN ARBOR,MI 48109
关键词
computed tomography (CT); comparative studies; emission CT (ECT); lung neoplasms; CT; staging;
D O I
10.1148/radiology.201.3.8939245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors quantitatively evaluated possible distortions of tumor size and shape introduced on non-attenuation-corrected 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) scans obtained in primary lung cancer tumors. Primary lung cancer tumors in 21 patients were measured on x-ray computed tomography (CT), attenuation-corrected FDG PET, and non-attenuation-corrected FDG PET scans. Apparent anteroposterior tumor dimensions on non-attenuation-corrected FDG PET scans were significantly larger (P = .0007; mean difference, 30%) than on attenuation-corrected FDG PET or CT scans (P = .05; mean difference, 28%). Left-to-right tumor dimensions on non-attenuation-corrected FDG PET scans were significantly smaller than on attenuation-corrected FDG PET scans (P = .03; mean difference, 8.5%) but were not significantly different from those on CT scans (P = .3).
引用
收藏
页码:873 / 876
页数:4
相关论文
共 21 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] BONI R, 1995, BRIT J DERMATOL, V132, P556
  • [3] DAHLBOM M, 1992, J NUCL MED, V33, P1191
  • [4] DETECTION OF PRIMARY AND RECURRENT LUNG-CANCER BY MEANS OF F-18 FLUORODEOXYGLUCOSE POSITRON EMISSION TOMOGRAPHY (FDG PET)
    DUHAYLONGSOD, FG
    LOWE, VJ
    PATZ, EF
    VAUGHN, AL
    COLEMAN, RE
    WOLFE, WG
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (01) : 130 - 140
  • [5] ACCURATE MEASUREMENT OF LIVER, KIDNEY, AND SPLEEN VOLUME AND MASS BY COMPUTERIZED AXIAL-TOMOGRAPHY
    HEYMSFIELD, SB
    FULENWIDER, T
    NORDLINGER, B
    BARLOW, R
    SONES, P
    KUTNER, M
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 90 (02) : 185 - 187
  • [6] CANCER-DETECTION WITH WHOLE-BODY PET USING 2-[F-18]FLUORO-2-DEOXY-D-GLUCOSE
    HOH, CK
    HAWKINS, RA
    GLASPY, JA
    DAHLBOM, M
    TSE, NY
    HOFFMAN, EJ
    SCHIEPERS, C
    CHOI, Y
    REGE, S
    NITZSCHE, E
    MADDAHI, J
    PHELPS, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (04) : 582 - 589
  • [7] HOH CK, 1994, WIEN KLIN WOCHENSCHR, V106, P496
  • [8] HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804
  • [9] HUBNER KF, 1995, CLIN NUCL MED, V20, P293
  • [10] SURVIVAL AND PROGNOSIS FOLLOWING RESECTION OF PRIMARY NON SMALL-CELL BRONCHOGENIC-CARCINOMA
    KADRI, MA
    DUSSEK, JE
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (03) : 132 - 136