Prospective evaluation of total hip arthroplasty with a cementless, anatomically designed, porous-coated femoral implant: Mean 11-year follow-up

被引:20
作者
Butler, JBV
Lansky, D
Duwelius, PJ
机构
[1] Orthoped & Fracture Clin PC, Portland, OR 97225 USA
[2] Fdn Accountabil, Portland, OR USA
关键词
anatomic design; femoral; quality of life; SF-36; titanium mesh; total hip arthroplasty;
D O I
10.1016/j.arth.2004.11.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Theperformance of an anatomically designed femoral implant with porous titanium mesh coating was assessed in patients undergoing total hip arthroplasty. The stem, with built-in 12 degrees anteversion, was implanted in neutral position relative to the long axis of the femur through a cementless press-fit application. The only requirement was the presence Of Sufficient thickness within the cortical bone of the femoral metaphysis to support the stem. Ninety-one evaluable patients were followed LIP for a minimum of 10 years. Patients tolerated weight-bearing activity within 24 hours after surgery. Only 1 femoral component required revision because of loosening. Most patients showed uniform bony ingrowth. Quality of life was markedly improved. The anatomically designed, porous-coated implant provides robust performance which has general utility in a wide range of patients.
引用
收藏
页码:709 / 716
页数:8
相关论文
共 45 条
[1]
Second-generation cementless total hip arthroplasty - Eight to eleven-year results [J].
Archibeck, MJ ;
Berger, RA ;
Jacobs, JJ ;
Quigley, LR ;
Gitelis, S ;
Rosenberg, AG ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11) :1666-1673
[2]
Avallone E.A., 1987, Mark's Standard Handbook for Mechanical Engineers
[3]
BERGER RA, 1997, CLIN ORTHOP RELAT R, V344, P216
[4]
The accuracy of assessing total hip arthroplasty outcomes - A prospective correlation study of walking ability and 2 validated measurement devices [J].
Boardman, DL ;
Dorey, F ;
Thomas, BJ ;
Lieberman, JR .
JOURNAL OF ARTHROPLASTY, 2000, 15 (02) :200-204
[5]
BOURNE RB, 1998, CLIN ORTHOP RELAT R, V355, P212
[6]
Brindley G W, 1998, J South Orthop Assoc, V7, P246
[7]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[8]
Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement [J].
Bugbee, WD ;
Culpepper, WJ ;
Engh, CA ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1007-1012
[9]
Cementless revision of total hip arthroplasty using the anatomic porous replacement revision prosthesis [J].
Buoncristiani, AM ;
Dorr, LD ;
Johnson, C ;
Wan, Z .
JOURNAL OF ARTHROPLASTY, 1997, 12 (04) :403-415
[10]
Primary total hip arthroplasty with use of the modular S-ROM prosthesis - Four to seven-year clinical and radiographic results [J].
Christie, MJ ;
DeBoer, DK ;
Trick, LW ;
Brothers, JC ;
Jones, RE ;
Vise, GT ;
Gruen, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12) :1707-1716