Temperature-responsive liquid chromatography .2. Effects of hydrophobic groups in N-isopropylacrylamide copolymer-modified silica

被引:212
作者
Kanazawa, H
Kashiwase, Y
Yamamoto, K
Matsushima, Y
Kikuchi, A
Sakurai, Y
Okano, T
机构
[1] KYORITSU COLL PHARMACEUT SCI,MINATO KU,TOKYO 105,JAPAN
[2] TOKYO WOMENS MED COLL,INST BIOMED ENGN,SHINJUKU KU,TOKYO 162,JAPAN
关键词
D O I
10.1021/ac961024k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We recently reported the new concept of temperature-responsive liquid chromatography using temperature-responsive poly(N-isopropylacrylamide)-modified surfaces as high-performance liquid chromatography media with aqueous mobile phases, Incorporation of hydrophobic sites is an important factor to improve the efficacy (selectivity and retention) of temperature-responsive chromatography. Toward this goal, we have synthesized semitelechelic copolymers of N-isopropylacrylamide (IPAAm) and butyl methacrylate (BMA) having reactive terminal functional groups using telomerization, The lower critical solution temperatures of the copolymers shift to lower temperatures with increasing hydrophobic BMA content in the poly(IPAAm-co-BMA) relative to that of the IPAAm homopolymer. This temperature-responsive semitelechelic copolymer was grafted to the surface of (aminopropyl)silica through the reaction of activated ester-amine coupling The polymer-modified silica was used as a column packing material. Separation of a mixture of five steroids having various hydrophobicities was investigated. Retention of steroids on poly(IPAAm-co-BMA)-modified columns is increased with an increase in column temperature. The capacity factors for steroids on the copolymer-modified silica beads was much larger than that on homopolymer PIPAAm-modified columns. The capacity factor for testosterone at 50 degrees C was 33.8 for poly(IPAAm-co-BMA) containing 5 mol % BMA, while that for the PIPAAm homopolymer was 15.0 at the same temperature. The influence of column temperature on steroid retention behavior on copolymer-modified stationary phases was significant compared with the case of homopolymer-modified columns. Furthermore, retention times for steroids increased remarkably with increasing BMA composition. The temperature-responsive elution behavior for the steroids was strongly affected by the hydrophobicity of the grafted polymer chains on silica surfaces. Possible protein separation in temperature-responsive liquid chromatography was explored using insulin chains A and B, and beta-endorphin fragment 1-27. On IBc-3.2-modified silica column, these three peptides were successfully separated at 30 degrees C with 0.5 M NaCl aqueous solution (pH 2.1) as mobile phase. The retention times of these peptides were related to the number of hydrophobic amino acid residues in the peptides. In the proposed chromatography system, elution of target substances is controlled only by a small change in column temperature without any further modification of the aqueous mobile phase.
引用
收藏
页码:823 / 830
页数:8
相关论文
共 25 条
  • [1] TEMPERATURE-DEPENDENCE OF SWELLING OF CROSS-LINKED POLY(N,N'-ALKYL SUBSTITUTED ACRYLAMIDES) IN WATER
    BAE, YH
    OKANO, T
    KIM, SW
    [J]. JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1990, 28 (06) : 923 - 936
  • [2] CHEN GH, 1994, J BIOMAT SCI-POLYM E, V5, P371
  • [3] PREPARATION AND PROPERTIES OF THERMOREVERSIBLE, PHASE-SEPARATING ENZYME-OLIGO(N-ISOPROPYLACRYLAMIDE) CONJUGATES
    CHEN, GH
    HOFFMAN, AS
    [J]. BIOCONJUGATE CHEMISTRY, 1993, 4 (06) : 509 - 514
  • [4] SITE-SPECIFIC CONJUGATION OF A TEMPERATURE-SENSITIVE POLYMER TO A GENETICALLY-ENGINEERED PROTEIN
    CHILKOTI, A
    CHEN, GH
    STAYTON, PS
    HOFFMAN, AS
    [J]. BIOCONJUGATE CHEMISTRY, 1994, 5 (06) : 504 - 507
  • [5] A SPECTROPHOTOMETRIC METHOD FOR THE ESTIMATION OF AMINO-GROUPS ON POLYMER SUPPORTS
    GAUR, RK
    GUPTA, KC
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 180 (02) : 253 - 258
  • [6] GEWEHR M, 1992, MAKROMOL CHEM, V193, P249
  • [7] Hansch C., 1995, Exploring QSAR-Fundamentals and Applications in Chemistry and Biology
  • [8] Heskins M., 1968, J. Macromol. Sci. Part A-Chem, V2, P1441, DOI [10.1080/10601326808051910, DOI 10.1080/10601326808051910]
  • [9] IN-SITU SURFACE-SELECTIVE MODIFICATION OF UNIFORM SIZE MACROPOROUS POLYMER PARTICLES WITH TEMPERATURE-RESPONSIVE POLY-N-ISOPROPYLACRYLAMIDE
    HOSOYA, K
    SAWADA, E
    KIMATA, K
    ARAKI, T
    TANAKA, N
    FRECHET, JMJ
    [J]. MACROMOLECULES, 1994, 27 (14) : 3973 - 3976
  • [10] TEMPERATURE-CONTROLLED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A UNIFORMLY SIZED TEMPERATURE-RESPONSIVE POLYMER-BASED PACKING MATERIAL
    HOSOYA, K
    KIMATA, K
    ARAKI, T
    TANAKA, N
    FRECHET, JMJ
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (11) : 1907 - 1911