Texture Feature Analysis for Computer-Aided Diagnosis on Pulmonary Nodules

被引:321
作者
Han, Fangfang [1 ,2 ]
Wang, Huafeng [1 ]
Zhang, Guopeng [3 ]
Han, Hao [1 ]
Song, Bowen [1 ,4 ]
Li, Lihong [5 ]
Moore, William [1 ]
Lu, Hongbing [3 ]
Zhao, Hong [2 ,7 ]
Liang, Zhengrong [1 ,6 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[2] Northeastern Univ, Shenyang 110819, Liaoning, Peoples R China
[3] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Shaanxi, Peoples R China
[4] SUNY Stony Brook, Dept Appl Math & Stat, Stony Brook, NY 11794 USA
[5] CUNY Coll Staten Isl, Dept Engn Sci & Phys, Staten Isl, NY 10314 USA
[6] SUNY Stony Brook, Stony Brook, NY 11794 USA
[7] Neusoft Co, Shenyang 110179, Liaoning, Peoples R China
基金
美国国家科学基金会;
关键词
Lung CADx; Lung nodule analysis; Haralick features; Gabor features; LBP features; HIGH-RESOLUTION CT; LUNG-CANCER; DIFFERENTIATING BENIGN; CLASSIFICATION; TOMOGRAPHY; GUIDELINES; MANAGEMENT; LIKELIHOOD; PATTERN; SCANS;
D O I
10.1007/s10278-014-9718-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Differentiation of malignant and benign pulmonary nodules is of paramount clinical importance. Texture features of pulmonary nodules in CT images reflect a powerful character of the malignancy in addition to the geometry-related measures. This study first compared three well-known types of two-dimensional (2D) texture features (Haralick, Gabor, and local binary patterns or local binary pattern features) on CADx of lung nodules using the largest public database founded by Lung Image Database Consortium and Image Database Resource Initiative and then investigated extension from 2D to three-dimensional (3D) space. Quantitative comparison measures were made by the well-established support vector machine (SVM) classifier, the area under the receiver operating characteristic curves (AUC) and the p values from hypothesis t tests. While the three feature types showed about 90 % differentiation rate, the Haralick features achieved the highest AUC value of 92.70 % at an adequate image slice thickness, where a thinner or thicker thickness will deteriorate the performance due to excessive image noise or loss of axial details. Gain was observed when calculating 2D features on all image slices as compared to the single largest slice. The 3D extension revealed potential gain when an optimal number of directions can be found. All the observations from this systematic investigation study on the three feature types can lead to the conclusions that the Haralick feature type is a better choice, the use of the full 3D data is beneficial, and an adequate tradeoff between image thickness and noise is desired for an optimal CADx performance. These conclusions provide a guideline for further research on lung nodule differentiation using CT imaging.
引用
收藏
页码:99 / 115
页数:17
相关论文
共 46 条
[1]
Principal component analysis [J].
Abdi, Herve ;
Williams, Lynne J. .
WILEY INTERDISCIPLINARY REVIEWS-COMPUTATIONAL STATISTICS, 2010, 2 (04) :433-459
[2]
Face description with local binary patterns:: Application to face recognition [J].
Ahonen, Timo ;
Hadid, Abdenour ;
Pietikainen, Matti .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2006, 28 (12) :2037-2041
[3]
Anand S. K. Vijai, 2010, 2010 International Conference on Communication Control and Computing Technologies, P518
[4]
Arai K, 2012, INT J ADV COMPUT SC, V3, P89
[5]
The Lung Image Database Consortium, (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans [J].
Armato, Samuel G., III ;
McLennan, Geoffrey ;
Bidaut, Luc ;
McNitt-Gray, Michael F. ;
Meyer, Charles R. ;
Reeves, Anthony P. ;
Zhao, Binsheng ;
Aberle, Denise R. ;
Henschke, Claudia I. ;
Hoffman, Eric A. ;
Kazerooni, Ella A. ;
MacMahon, Heber ;
van Beek, Edwin J. R. ;
Yankelevitz, David ;
Biancardi, Alberto M. ;
Bland, Peyton H. ;
Brown, Matthew S. ;
Engelmann, Roger M. ;
Laderach, Gary E. ;
Max, Daniel ;
Pais, Richard C. ;
Qing, David P-Y ;
Roberts, Rachael Y. ;
Smith, Amanda R. ;
Starkey, Adam ;
Batra, Poonam ;
Caligiuri, Philip ;
Farooqi, Ali ;
Gladish, Gregory W. ;
Jude, C. Matilda ;
Munden, Reginald F. ;
Petkovska, Iva ;
Quint, Leslie E. ;
Schwartz, Lawrence H. ;
Sundaram, Baskaran ;
Dodd, Lori E. ;
Fenimore, Charles ;
Gur, David ;
Petrick, Nicholas ;
Freymann, John ;
Kirby, Justin ;
Hughes, Brian ;
Casteele, Alessi Vande ;
Gupte, Sangeeta ;
Sallam, Maha ;
Heath, Michael D. ;
Kuhn, Michael H. ;
Dharaiya, Ekta ;
Burns, Richard ;
Fryd, David S. .
MEDICAL PHYSICS, 2011, 38 (02) :915-931
[6]
Videothoracoscopic management of the solitary pulmonary nodule: A single-institution study on 429 cases [J].
Cardillo, G ;
Regal, M ;
Sera, F ;
Di Martino, M ;
Carbone, L ;
Facciolo, F ;
Martelli, M .
ANNALS OF THORACIC SURGERY, 2003, 75 (05) :1607-1611
[7]
El-Baz A, 2012, 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), P1463, DOI 10.1109/ISBI.2012.6235847
[8]
El-Baz A, 2011, I S BIOMED IMAGING, P137, DOI 10.1109/ISBI.2011.5872373
[9]
APPEARANCE ANALYSIS FOR DIAGNOSING MALIGNANT LUNG NODULES [J].
El-Baz, Ayman ;
Gimel'farb, Georgy ;
Falk, Robert ;
El-Ghar, Mohamed .
2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, :193-196
[10]
El-Baz A, 2011, LECT NOTES COMPUT SC, V6801, P772, DOI 10.1007/978-3-642-22092-0_63