Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems

被引:59
作者
Kirisits, Christian [1 ]
Siebert, Frank-Andre
Baltas, Dimos
De Brabandere, Marisol
Hellebust, Taran Paulsen
Berger, Daniel
Venselaar, Jack
机构
[1] Med Univ Vienna, Dept Radiotherapy, Vienna, Austria
[2] Univ Hosp Schleswig Holstein, Clin Radiotherapy, Kiel, Germany
[3] Dept Med Phys & Engn, Offenbach, Germany
[4] Univ Hosp Gasthuisberg, Dept Radiotherapy, B-3000 Louvain, Belgium
[5] Natl Hosp Norway, Radium Hosp Hlth Trust, Dept Med Phys, Oslo, Norway
[6] Dr B Verbeeten Inst, Dept Radiotherapy, Tilburg, Netherlands
关键词
brachytherapy; treatment planning; dose volume histogram calculation;
D O I
10.1016/j.radonc.2007.06.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. To determine the uncertainties in dose volume histogram (DVH) analysis used in modern brachytherapy treatment planning systems (TPSs). Materials and methods. A phantom with three different volumes was scanned with CT and MRI. An inter-observer analysis was based on contouring performed by 5 persons. The volume of a standard contour set was calculated using seven different TPSs. For five systems a typical brachytherapy dose distribution was used to compare DVH determination. Results. The inter-observer variability (1SD)was 13% for a small cylindrical volume, 5% for a large cylinder and 3% for a conical shape. A standardized volume for a 4 mm CT scan contoured on seven different TPS varied by 7%, 2%, and 5% (1SD). Use of smaller slice thickness reduced the variations. A treatment plan with the sources between the large cylindrical shape and the cone showed variations for D-2cc of 1% and 5% (110), respectively. Deviations larger than 10% were observed for a smaller source to cylinder surface distance of 5 mm. Conclusions. Modern TPSs minimize the volumetric and dosimetric calculation uncertainties. These are comparable to inter-observer contouring variations. However, differences in volume result from the methods of calculation in the first and last slice of a contoured structure. For this situation and in case of high dose gradients inside analyzed volumes, high uncertainties were observed. The use of DVH parameters in clinical practice should take into account the method of calculation and the possible uncertainties. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:290 / 297
页数:8
相关论文
共 19 条
[1]   Acute genitourinary toxicity after high dose rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Second analysis to determine the correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity [J].
Akimoto, T ;
Katoh, H ;
Noda, S ;
Ito, K ;
Yamamoto, T ;
Kashiwagi, B ;
Nakano, T .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02) :472-478
[2]   ESTRO/EAU/EORTC recommendations on permanent seed implantation for localized prostate cancer [J].
Ash, D ;
Flynn, A ;
Battermann, J ;
de Reijke, T ;
Lavagnini, P ;
Blank, L .
RADIOTHERAPY AND ONCOLOGY, 2000, 57 (03) :315-321
[3]   The correlation between D90 and outcome for l-125 seed implant monotherapy for localised prostate cancer [J].
Ash, Dan ;
Al-Qaisieh, Bashar ;
Bottomley, David ;
Carey, Brendan ;
Joseph, Joji .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) :185-189
[4]   Comparison of dose length, area, and volume histograms as quantifiers of urethral dose in prostate brachytherapy [J].
Butler, WM ;
Merrick, GS ;
Dorsey, AT ;
Hagedorn, BM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1575-1582
[5]  
Crook Juanita, 2002, Brachytherapy, V1, P66, DOI 10.1016/S1538-4721(02)00014-4
[6]  
Crook Juanita M, 2005, Brachytherapy, V4, P186, DOI 10.1016/j.brachy.2005.01.002
[7]  
Fellner C, 1998, STRAHLENTHER ONKOL, V174, P345, DOI 10.1007/BF03038347
[8]   Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group* (I):: concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV [J].
Haie-Meder, C ;
Pötter, R ;
Van Limbergen, E ;
Briot, E ;
De Brabandere, M ;
Dimopoulos, J ;
Dumas, I ;
Hellebust, TP ;
Kirisits, C ;
Lang, SF ;
Muschitz, S ;
Nevinson, J ;
Nulens, A ;
Petrow, P ;
Wachter-Gerstner, N .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (03) :235-245
[9]  
HAN BH, 2003, MED PHYS, V30
[10]   Inter fraction variations in rectum and bladder volumes and dose distributions during high dose rate brachytherapy treatment of the uterine cervix investigated by repetitive CT-examinations [J].
Hellebust, TP ;
Dale, E ;
Skjonsberg, A ;
Olsen, DR .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) :273-280