Automated particle electrophoresis: Modeling and control of adverse chamber surface properties

被引:6
作者
Knox, RJ
Burns, NL
Van Alstine, JM [1 ]
Harris, JM
Seaman, GVF
机构
[1] Royal Inst Technol, Dept Chem Engn & Technol, SE-10044 Stockholm, Sweden
[2] Emerald Diagnost, Eugene, OR 97402 USA
[3] Inst Surface Chem, SE-11486 Stockholm, Sweden
[4] Univ Alabama, Dept Chem, Huntsville, AL 35899 USA
关键词
D O I
10.1021/ac970913k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrophoretic analysis of colloidal particles is adversely affected by a host of surface phenomena, including electroosmosis, phase wall wetting, and sample or air bubble adsorption. Neutral, hydrophilic polymer coatings control such phenomena on a variety of surfaces. Poly(ethylene glycol)-poly(ethylene imine) (PEG-PEI) conjugates significantly reduce electroosmosis and positively control adsorption and wetting in the glass sample chambers (5 mm x 3 mm x 1 mm i.d.) employed in a representative commercial electrophoresis apparatus (Coulter DELSA 440). The reduction in electroosmosis (e.g., 80% in 7.5 mM solution at pH II) was similar to that exhibited by coated 2-mm-i.d. quartz capillaries in a Rank MK I manual apparatus, PEG-PEI coatings significantly reduce electroosmosis over a wide range of pH (2-11) and ionic strength (1-100 mM) and can be stable for weeks under normal laboratory conditions, They greatly enhance ease of operation and accuracy (sample mean electrophoretic mobility +/- SD) of the DELSA 440. The latter results from reduced electroosmosis now profile gradients near the chamber center-axis stationary levels, where particle mobility is typically measured. Such flow profiles may also be affected by chamber wall surface asymmetries. A hydrodynamic description of electroosmotic fluid now in rectangular chambers was adapted in order to analyze the propagation of errors due to both nonideal focusing and chamber surface asymmetry. The analysis indicated that the accuracy of rectangular chambered devices may be improved by measuring particle mobility at stationary levels different than chamber center axes. As a result, some rectangular chambers may confer accuracy advantages over cylindrical chambers.
引用
收藏
页码:2268 / 2279
页数:12
相关论文
共 37 条
[1]   CATION EXCHANGE IN POROUS GLASS [J].
ALTUG, I ;
HAIR, ML .
JOURNAL OF PHYSICAL CHEMISTRY, 1967, 71 (13) :4260-&
[2]  
BERGSTROM K, 1994, J BIOMAT SCI-POLYM E, V6, P123
[3]   USING POLY(ETHYLENE IMINE) TO GRAFT POLY(ETHYLENE GLYCOL) OR POLYSACCHARIDE TO POLYSTYRENE [J].
BRINK, C ;
OSTERBERG, E ;
HOLMBERG, K ;
TIBERG, F .
COLLOIDS AND SURFACES, 1992, 66 (02) :149-156
[4]   Surface characterization through measurement of electroosmosis at flat plates [J].
Burns, NL .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1996, 183 (01) :249-259
[5]   POLY(ETHYLENE GLYCOL) GRAFTED TO QUARTZ - ANALYSIS IN TERMS OF A SITE-DISSOCIATION MODEL OF ELECTROOSMOTIC FLUID-FLOW [J].
BURNS, NL ;
VANALSTINE, JM ;
HARRIS, JM .
LANGMUIR, 1995, 11 (07) :2768-2776
[6]  
BURNS NL, IN PRESS BIOMATERIAL
[7]   STRUCTURAL CHARACTERIZATION OF (3-AMINOPROPYL)TRIETHOXYSILANE-MODIFIED SILICAS BY SI-29 AND C-13 NUCLEAR MAGNETIC-RESONANCE [J].
CARAVAJAL, GS ;
LEYDEN, DE ;
QUINTING, GR ;
MACIEL, GE .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1776-1786
[8]   Adsorption and interaction of a graft copolymer of poly(ethylene imine) and poly(ethylene oxide) [J].
Claesson, PM ;
Blomberg, E ;
Paulson, O ;
Malmsten, M .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1996, 112 (2-3) :131-139
[9]   Grafting poly(ethylene glycol) epoxide to amino-derivatized quartz: Effect of temperature and pH on grafting density [J].
Emoto, K ;
Harris, JM ;
VanAlstine, JM .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3751-3757
[10]   CAPILLARY ZONE ELECTROPHORESIS SEPARATIONS OF BASIC AND ACIDIC PROTEINS USING POLY(VINYL ALCOHOL) COATINGS IN FUSED-SILICA CAPILLARIES [J].
GILGES, M ;
KLEEMISS, MH ;
SCHOMBURG, G .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2038-2046