Electrochemical analysis of D-penicillamine using a carbon paste electrode modified with ferrocene carboxylic acid

被引:33
作者
Raoof, Jahan-Bakhsh [1 ]
Ojani, Reza [1 ]
Chekin, Freshteh [1 ]
机构
[1] Mazandaran Univ, Fac Basic Sci, Dept Chem, Electroanalyt Chem Res Lab, Babol Sar, Iran
关键词
ferrocene carboxylic acid; penicillamine; electrocatalysis; carbon paste electrode; differential pulse voltammetry; cyclic voltammetry; LIQUID-CHROMATOGRAPHY; ELECTROCATALYTIC DETERMINATION; VOLTAMMETRIC DETERMINATION; AMPEROMETRIC DETECTION; SULFHYDRYL COMPOUNDS; DOSAGE FORMS; OXIDATION; CYSTEINE; SURFACE; THIOLS;
D O I
10.1002/elan.200703947
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behavior Of D-penicillamine (D-PA) studied at the surface of ferrocene carboxylic acid modified carbon paste electrode (FCAMCPE) in aqueous media using cyclic voltammetry and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00), the oxidation Of D-PA at surface of such an electrode is occurred about 420 mV less positive than that an unmodified carbon paste electrode (CPE). The catalytic oxidation peak current was linearly dependent on the D-PA concentration and a linear calibration curve was obtained in the ranges 7.5 x 10(-5) M-1.0 x 10(-3) M and 6.5 x 10(-1) M-1.0 x 10(-4) M of D-PA with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3 sigma) were determined as 6.04 x 10(-5) M and 6.15 x 10(-6) M. This method was also used for the determination of D-PA in pharmaceutical preparation (capsules) by standard addition method.
引用
收藏
页码:1883 / 1889
页数:7
相关论文
共 53 条
[3]   In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine [J].
Corominas, BGT ;
Pferzschner, J ;
Catalá-Icardo, M ;
Zamora, LL ;
Calatayud, JM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (1-2) :281-284
[4]  
DROSOS AA, 1993, CLIN EXP RHEUMATOL, V11, P387
[5]   Determination of pharmaceutical thiols by liquid chromatography with electrochemical detection: Use of an electrode with a conductive carbon cement matrix, chemically modified with cobalt phthalocyanine [J].
Favaro, G ;
Fiorani, M .
ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) :249-255
[6]  
Galus Z., 1976, Fundamental of electrochemical analysis
[7]   CHEMICALLY MODIFIED CARBON PASTE ELECTRODES .4. ELECTROSTATIC BINDING AND ELECTROCATALYSIS AT POLY(4-VINYLPYRIDINE)-CONTAINING ELECTRODES [J].
GENO, PW ;
RAVICHANDRAN, K ;
BALDWIN, RP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 183 (1-2) :155-166
[8]   Catalysis of dioxygen reduction to hydrogen peroxide at the surface of carbon paste electrodes modified by 1,4-naphthoquinone and some of its derivatives [J].
Golabi, SM ;
Raoof, JB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 416 (1-2) :75-82
[9]   Effect of chelating agents on the excretion of copper, zinc and iron in the bile and urine of sheep [J].
Gooneratne, SR ;
Christensen, DA .
VETERINARY JOURNAL, 1997, 153 (02) :171-178
[10]   VOLTAMMETRIC BEHAVIOR OF VITAMIN-B1 (THIAMINE) AT A GLASSY-CARBON ELECTRODE AND ITS DETERMINATION IN MULTIVITAMIN TABLETS USING ANION-EXCHANGE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION UNDER BASIC CONDITIONS [J].
HART, JP ;
NORMAN, MD ;
TSANG, S .
ANALYST, 1995, 120 (04) :1059-1064