Analysis of the receiver response in lidar measurements

被引:44
作者
Velotta, R
Bartoli, B
Capobianco, R
Fiorani, L
Spinelli, N
机构
[1] Complesso Univ Monte S Angelo, INFM, Italian Inst Matter Phys, I-80126 Naples, Italy
[2] Univ Naples Federico II, Dipartimento Sci Fis, Naples, Italy
[3] Ist Nazl Fis Nucl, Italian Inst Nucl Phys, I-80125 Naples, Italy
[4] CNR, IMAAA, I-85050 Tito Sclao, PZ, Italy
[5] CORISTA, I-80125 Naples, Italy
[6] Univ Basilicata, Dipartimento Ingn & Fis Ambiente, I-85100 Potenza, Italy
来源
APPLIED OPTICS | 1998年 / 37卷 / 30期
关键词
D O I
10.1364/AO.37.006999
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report on the calculation of the effective telescope area in lidar applications by a ray-tracing approach. This method allows one to consider the true experimental working conditions and hence to obtain accurate values of the effective telescope area as a function of the height. This in turn allows the retrieval of the signal from the ranges where the overlap function is not constant (e.g., lower ranges), thus increasing the useful range interval. Moreover, we show that the spherical mirrors are more appropriate than the parabolic ones for most of the lidar measurements, although a particular alignment procedure, such as the one we describe, must be used. (C) 1998 Optical Society of America.
引用
收藏
页码:6999 / 7007
页数:9
相关论文
共 12 条
[1]   LIDAR TELESCOPE OVERLAP FUNCTION AND EFFECTS OF MISALIGNMENT FOR UNSTABLE RESONATOR TRANSMITTER AND COHERENT RECEIVER [J].
ANCELLET, GM ;
KAVAYA, MJ ;
MENZIES, RT ;
BROTHERS, AM .
APPLIED OPTICS, 1986, 25 (17) :2886-2890
[2]  
Collins R.T. H., 1976, Topics in Applied Physics, V14, P71, DOI [10.1007/3-540-07743-X_18, DOI 10.1007/3-540-07743-X_18]
[3]   Tropospheric ozone measurements over the great Athens area during the MEDCAPHOT-TRACE campaign with a new shot-per-shot DIAL instrument: Experimental system and results [J].
Durieux, E ;
Fiorani, L ;
Calpini, B ;
Flamm, M ;
Jaquet, L ;
Van Den Bergh, H .
ATMOSPHERIC ENVIRONMENT, 1998, 32 (12) :2141-2150
[4]   Self-aligning lidar for the continuous monitoring of the atmosphere [J].
Fiorani, L ;
Armenante, M ;
Capobianco, R ;
Spinelli, N ;
Wang, X .
APPLIED OPTICS, 1998, 37 (21) :4758-4764
[5]  
FIORANI L, 1996, THESIS ECOLE POLYTEC
[6]   GEOMETRICAL FORM-FACTORS FOR LIDAR FUNCTION [J].
HALLDORSSON, T ;
LANGERHOLC, J .
APPLIED OPTICS, 1978, 17 (02) :240-244
[7]   GEOMETRICAL COMPRESSION OF LIDAR RETURN SIGNALS [J].
HARMS, J ;
LAHMANN, W ;
WEITKAMP, C .
APPLIED OPTICS, 1978, 17 (07) :1131-1135
[8]   LIDAR RETURN SIGNALS FOR COAXIAL AND NON-COAXIAL SYSTEMS WITH CENTRAL OBSTRUCTION [J].
HARMS, J .
APPLIED OPTICS, 1979, 18 (10) :1559-1566
[9]  
Measure R. M., 1984, LASER REMOTE SENSING
[10]  
RUTTEN H, 1989, TELESCOPE OPTICS