Solution Densities and Estimated Total Protein Contents Associated With Inappropriate Flotation of Separator Gel in Different Blood Collection Tubes

被引:17
作者
Faught, Ronald C. [2 ]
Marshall, James [2 ]
Bornhorst, Joshua [1 ]
机构
[1] Univ Arkansas Med Sci, Coll Med, Dept Pathol, Little Rock, AR 72205 USA
[2] Univ Arkansas Med Sci, Clin Lab, Little Rock, AR 72205 USA
关键词
D O I
10.5858/2010-0488-OAR.1
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Clinical samples that have densities greater than that of separator gel in specimen tubes may exhibit gel flotation to the top of the specimen upon centrifugation. Inappropriate separator gel flotation can occur in specimens with high protein content. In automated analytical systems, gel flotation can lead to mechanical disruption and potential inaccurate result reporting upon aspiration into instrument sampling probes. Objective.-To determine the relative specimen densities and estimated total protein contents at which specimen gel flotation would occur upon centrifugation in commonly used commercial specimen tubes, a comparative study of separator gel density was initiated using prepared dextran solutions. Design.-Specific gravity of several dextran solutions was determined by direct hydrometry. The dextran solutions were introduced to serum and plasma lithium heparin BD Vacutainer specimen tubes manufactured by Becton, Dickinson and Company and into Vacuette specimen tubes manufactured by Greiner Bio-One containing separator gel. Following centrifugation the specimen tubes were examined for gel flotation. Results.-Flotation was observed at a lower dextran solution density for Greiner than for BD tubes in both serum and plasma separator gel specimen tubes. Additionally, some differences between specimen tube lots were observed for both BD and Greiner tubes. The total protein content in clinical samples that would result in gel flotation can be estimated for different specimen container types. Conclusions.-Differences were observed for the gel separator specific gravity in different blood collection containers. Laboratories wishing to avoid problems with inappropriate gel flotation in high protein samples should consider these observations. (Arch Pathol Lab Med. 2011; 135: 1081-1084)
引用
收藏
页码:1081 / 1084
页数:4
相关论文
共 7 条
[1]   Measurement of urine relative density using refractometer and reagent strips [J].
Dorizzi, RM ;
Caputo, M .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (12) :925-928
[2]   Anomalous flotation of separator gel:: Density or viscosity? [J].
Fatas, Maria ;
Franquelo, Pablo ;
Franquelo, Ricardo .
CLINICAL CHEMISTRY, 2008, 54 (04) :771-772
[3]   Multiple myeloma [J].
Kyle, Robert A. ;
Rajkumar, S. Vincent .
BLOOD, 2008, 111 (06) :2962-2972
[4]   The relationships between plasma specific gravity, plasma protein content and edema in nephritis [J].
Moore, NS ;
Van Slyke, DD .
JOURNAL OF CLINICAL INVESTIGATION, 1930, 8 (03) :337-355
[5]   Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use [J].
O'Keane, Myra P. ;
Cunningham, Sean K. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (05) :662-668
[6]   The case of the floating gel [J].
Srivastava, R ;
Murphy, MJ ;
Card, J ;
Severn, A ;
Fraser, CG .
JOURNAL OF CLINICAL PATHOLOGY, 2004, 57 (12) :1333-1334
[7]   High total protein impairs appropriate gel barrier formation in BD vacutainer blood collection tubes [J].
van den Ouweland, Johannes M. W. ;
Church, Stephan .
CLINICAL CHEMISTRY, 2007, 53 (02) :364-365