Motion artifacts of the aorta simulating aortic dissection on spiral CT

被引:42
作者
Qanadli, SD [1 ]
El Hajjam, M [1 ]
Mesurolle, B [1 ]
Lavisse, L [1 ]
Jourdan, O [1 ]
Randoux, B [1 ]
Chagnon, S [1 ]
Lacombe, P [1 ]
机构
[1] Univ Paris 05, Hop Ambroise Pare, Serv Radiol, F-92104 Boulogne, France
关键词
computed tomography; spiral; artifact; helical; aorta; aorta dissection;
D O I
10.1097/00004728-199901000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Motion artifacts of the ascending aorta may impair image quality and simulate an intimal flap or a false channel. The purpose of this study is to evaluate the prevalence, amplitude, and extent of motion artifacts of the aorta in spiral CT and to specify the effects of acquisition and reconstruction parameters on these artifacts. Method: One hundred seventy-one thoracic spiral CT examinations were retrospectively analyzed by two reviewers. The analysis sought to determine the presence, location, amplitude, and extent of artifacts of the ascending aorta. Results: Aortic artifacts were detected on spiral CT in 57% of cases. The mean amplitude and mean extent were 4 +/- 4 and 6 +/- 7 mm, respectively. Artifacts in the ascending aorta were significantly higher with the 360 degrees linear interpolation (LI) algorithm than with the 180 degrees LI algorithm. Conclusion: The prevalence of motion artifacts on spiral CT is higher in this study than the reported prevalence in incremental CT. However, this higher prevalence is significantly reduced when the 180 degrees LI algorithm is used.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 13 条
[1]   MOTION ARTIFACT SIMULATING AORTIC DISSECTION ON CT [J].
BURNS, MA ;
MOLINA, PL ;
GUTIERREZ, FR ;
SAGEL, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) :465-467
[2]   AORTIC MOTION - A POTENTIAL PITFALL IN CT IMAGING OF DISSECTION IN THE ASCENDING AORTA [J].
DUVERNOY, O ;
COULDEN, R ;
YTTERBERG, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (04) :569-572
[3]   ACUTE AORTIC DISSECTION - TYPICAL AND ATYPICAL IMAGING FEATURES [J].
FISHER, ER ;
STERN, EJ ;
GODWIN, JD ;
OTTO, CM ;
JOHNSON, JA .
RADIOGRAPHICS, 1994, 14 (06) :1263-1271
[4]   STREAK ARTIFACTS OF THE THORACIC AORTA - PSEUDODISSECTION [J].
GALLAGHER, S ;
DIXON, AK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :688-693
[5]   PROBLEMS AND PITFALLS IN THE EVALUATION OF THORACIC AORTIC DISSECTION BY COMPUTED-TOMOGRAPHY [J].
GODWIN, JD ;
BREIMAN, RS ;
SPECKMAN, JM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (04) :750-756
[6]   Spiral CT artifact that simulates aortic dissection: Image reconstruction with use of 180 degrees and 360 degrees linear-interpolation algorithms [J].
Loubeyre, P ;
Angelie, E ;
Grozel, F ;
Abidi, H ;
Van, ATM .
RADIOLOGY, 1997, 205 (01) :153-157
[7]   Prevalence of motion artifact simulating aortic dissection on spiral CT using a 180 degrees linear interpolation algorithm for reconstruction of the images [J].
Loubeyre, P ;
Grozel, F ;
Carrillon, Y ;
Galliard, C ;
Pellet, O ;
Minh, VAT .
EUROPEAN RADIOLOGY, 1997, 7 (03) :320-322
[8]   MOTION ARTIFACT SIMULATING AORTIC DISSECTION ON CT [J].
MUKHERJI, SK ;
VARMA, P ;
STARK, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (03) :674-674
[9]   EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT [J].
POLACIN, A ;
KALENDER, WA ;
MARCHAL, G .
RADIOLOGY, 1992, 185 (01) :29-35
[10]   MOTION ARTIFACT SIMULATING AORTIC DISSECTION [J].
POSNIAK, H ;
OLSON, M ;
DEMOS, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) :420-420