Nonpalpable breast cancer: Percutaneous diagnosis with 11-and 8-gauge stereotactic vacuum-assisted biopsy devices

被引:52
作者
Brem, RF
Schoonjans, JM
Goodman, SN
Nolten, A
Askin, FB
Gatewood, OMB
机构
[1] George Washington Univ, Dept Radiol, Breast Imaging & Intervent Ctr, Med Ctr, Washington, DC 20037 USA
[2] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[3] Johns Hopkins Med Inst, Dept Oncol, Baltimore, MD USA
[4] Johns Hopkins Med Inst, Dept Pathol, Baltimore, MD USA
[5] Johns Hopkins Med Inst, Dept Pathol, Baltimore, MD USA
[6] Johns Hopkins Med Inst, Breast Imaging & Int Ctr, Baltimore, MD USA
关键词
biopsies; technology; breast; biopsy; diseases; breast neoplasms; diagnosis;
D O I
10.1148/radiology.219.3.r01jn34793
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of diagnosis of invasive breast cancer with 11- and 8-gauge stereotactic vacuum-assisted biopsy (SVAB) devices and to correlate lesion diameter and accuracy of breast cancer diagnosis at SVAB. MATERIALS AND METHODS: During a 22-month period, 489 SVAB procedures were performed with an 11-gauge probe and 305 with an 8-gauge probe. SVAB and surgical pathologic results of 104 breast carcinomas were reviewed and correlated with lesion size, number of specimens obtained, and type of SVAB probe used. RESULTS: Four of 38 ductal carcinoma in situ (DCIS) lesions diagnosed with 11-gauge SVAB demonstrated invasion at surgery, whereas one of 23 DCIS lesions diagnosed with 8-gauge SVAB demonstrated invasion at surgery (P = .6). A mean of 12 specimens per lesion were obtained in each group. In lesions 30 mm or larger, the underestimation rate for DCIS was 43% (three of seven) with 11-gauge SVAB and 17% (one of six) with 8-gauge SVAB (P = .6). Overall, the rate of underestimation for DCIS was significantly higher in lesions 30 mm or larger (four of 13)than in smaller lesions tone of 48, P = .006). CONCLUSION: This study demonstrated no difference in breast cancer diagnosis with the 8- and 11-gauge SVAB systems, but the accuracy of breast cancer diagnosis was greater in lesions smaller than 30 mm than in larger lesions.
引用
收藏
页码:793 / 796
页数:4
相关论文
共 21 条
  • [1] Stereotactic core-needle biopsy of the breast: A report of the joint task force of the American College of Radiology, American College of Surgeons, and College of American Pathologists
    Bassett, L
    Winchester, DP
    Caplan, RB
    Dershaw, DD
    Dowlatshahi, K
    Evans, WP
    Fajardo, LL
    Fitzgibbons, PL
    Henson, DE
    Hutter, RVP
    Morrow, M
    Paquelet, JR
    Singletary, SE
    Curry, J
    WilcoxBuchalla, P
    Zinninger, M
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 1997, 47 (03) : 171 - +
  • [2] Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model
    Berg, WA
    Krebs, TL
    Campassi, C
    Magder, LS
    Sun, CCJ
    [J]. RADIOLOGY, 1997, 205 (01) : 203 - 208
  • [3] Atypical ductal hyperplasia: Histologic underestimation of carcinoma in tissue harvested from impalpable breast lesions using 11-gauge stereotactically guided directional vacuum-assisted biopsy
    Brem, RF
    Behrndt, VS
    Sanow, L
    Gatewood, OMB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1405 - 1407
  • [4] Selection of core biopsy specimens for pathologic evaluation of targeted microcalcifications
    Brem, RF
    Askin, FB
    Gatewood, OMB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) : 901 - 902
  • [5] Brem RF, 1998, RADIOLOGY, V209, P519
  • [6] Burbank F, 1996, AM SURGEON, V62, P738
  • [7] Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy
    Burbank, F
    [J]. RADIOLOGY, 1997, 202 (03) : 843 - 847
  • [8] Burbank F, 1997, AM SURGEON, V63, P988
  • [9] Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: Improved reliability with 14-gauge, directional, vacuum-assisted biopsy
    Jackman, RJ
    Burbank, F
    Parker, SH
    Evans, WP
    Lechner, MC
    Richardson, TR
    Tocino, I
    Wray, AB
    [J]. RADIOLOGY, 1997, 204 (02) : 485 - 488
  • [10] Percutaneous removal of benign mammographic lesions: Comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques
    Jackman, RJ
    Marzoni, FA
    Nowels, KW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) : 1325 - 1330