SQUARE-WAVE ANODIC STRIPPING VOLTAMMETRY (SWASV) FOR THE DETERMINATION OF ECOTOXIC METALS, USING A BISMUTH-FILM ELECTRODE

被引:26
作者
Anastasiadou, Z. D. [2 ]
Sipaki, I. [1 ]
Jannakoudakis, P. D. [2 ]
Girousi, S. T. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Analyt Chem Lab, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Phys Chem Lab, Thessaloniki 54124, Greece
关键词
Anodic stripping voltammetry; Bismuth-film electrode; Ecotoxic metals; Reference materials; IN-SITU MEASUREMENTS; TRACE-METALS; HEAVY-METALS; COPPER; CD(II); PB(II); INTERFERENCES; SUPPRESSION; CADMIUM; GALLIUM;
D O I
10.1080/00032711003790023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reviews the use of square wave anodic stripping voltammetry for the simultaneous determination of ecotoxic metals (Pb, Cd, Cu, and Zn) on a bismuth-film (BiFE) electrode. The BiFE was prepared in situ on a glassy-carbon electrode (GCE) from the 0.1 mol L-1 acetate buffer solution (pH 4.5) containing 200 mu g L-1 of bismuth (III). The addition of hydrogen peroxide to the electroanalytical cell proved beneficial for the interference-free determination of Cu (II) together with zinc, lead, and cadmium, using the BiFE. The experimental variables were investigated and optimized with the view to apply this type of voltammetric sensor to real samples containing traces of these metals. The performance characteristics, such as reproducibility, decision limit (CC alpha), detection capability (CC beta), sensitivity, and accuracy indicated that the method holds promise for trace Cu2+, Pb2+, Cd2+, and Zn2+ levels by employment of Hg-free GCE with SWASV. CC alpha, and CC beta were calculated according to the Commission Decision of 12 August 2002 (2002/657/EC). Linearity was observed in the range 20-280 mu g L-1 for zinc, 10-100 mu g L-1 for lead, 10-80 mu g L-1 for copper, and 5-50 mu g L-1 for cadmium. Using the optimized conditions, the stripping performance of the BiFE was characterized by low limits of detection (LOD). Finally, the method was successfully applied in real as well as in certified reference water samples.
引用
收藏
页码:761 / 777
页数:17
相关论文
共 42 条
[1]   Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters [J].
Achterberg, EP ;
Braungardt, C .
ANALYTICA CHIMICA ACTA, 1999, 400 :381-397
[2]   Determination of heavy metals in wines by anodic stripping voltammetry with thick-film modified electrode [J].
Brainina, KZ ;
Stozhko, NY ;
Belysheva, GM ;
Inzhevatova, OV ;
Kolyadina, LI ;
Cremisini, C ;
Galletti, M .
ANALYTICA CHIMICA ACTA, 2004, 514 (02) :227-234
[3]   Sensitive stripping voltammetry of heavy metals by using a composite sensor based on a built-in bismuth precursor [J].
Castañeda, MT ;
Pérez, B ;
Pumera, M ;
del Valle, M ;
Merkoçi, A ;
Alegret, S .
ANALYST, 2005, 130 (06) :971-976
[4]   A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetry [J].
Charalambous, A ;
Economou, A .
ANALYTICA CHIMICA ACTA, 2005, 547 (01) :53-58
[5]   Determination of trace heavy metals by sequential injection-anodic stripping voltammetry using bismuth film screen-printed carbon electrode [J].
Chuanuwatanakul, Suchada ;
Dungchai, Wijitar ;
Chailapakul, Orawon ;
Motomizu, Shoji .
ANALYTICAL SCIENCES, 2008, 24 (05) :589-594
[6]   Simultaneous determination of cadmium, lead, copper, and thallium in highly saline samples by anodic stripping voltammetry (ASV) using mercury-film and bismuth-film electrodes [J].
de Carvalho, Leandro M. ;
do Nasciniento, Paulo C. ;
Koschinsky, Andrea ;
Bau, Michael ;
Stefanello, Raquel F. ;
Spengler, Cristiane ;
Bohrer, Denise ;
Jost, Cristiane .
ELECTROANALYSIS, 2007, 19 (16) :1719-1726
[7]   A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry [J].
Demetriades, D ;
Economou, A ;
Voulgaropoulos, A .
ANALYTICA CHIMICA ACTA, 2004, 519 (02) :167-172
[8]   Bismuth-film electrodes: recent developments and potentialities for electroanalysis [J].
Economou, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) :334-340
[9]   Determination of amlodipine besylate by adsorptive square-wave anodic stripping voltammetry on glassy carbon electrode in tablets and biological fluids [J].
Gazy, AAK .
TALANTA, 2004, 62 (03) :575-582
[10]   Modification of carbon screen-printed electrodes by adsorption of chemically synthesized Bi nanoparticles for the voltammetric stripping detection of Zn(II), Cd(II) and Pb(II) [J].
Granado Rico, Ma Angeles ;
Olivares-Marin, Mara ;
Pinilla Gil, Eduardo .
TALANTA, 2009, 80 (02) :631-635