Short-TE localised 1H MRS of the human brain at 3T:: quantification of the metabolite signals using two approaches to account for macromolecular signal contributions

被引:42
作者
Gottschalk, Michael [1 ,2 ]
Lamalle, Laurent [3 ]
Segebarth, Christoph [2 ]
机构
[1] Equipe Neuroimagerie Fonct & Metab, Ctr Rech Inserm U UJF CEA CHU 836, GIN, F-38042 Grenoble 9, France
[2] Univ Grenoble 1, Grenoble Inst Neurosci, Grenoble, France
[3] IFR 1, INSERM, Grenoble, France
关键词
H-1 NMR spectroscopy; short-TE PRESS; 3T; QUEST; quantification; parietal white matter;
D O I
10.1002/nbm.1219
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The goal of this study was to validate metabolite quantification at short TE, with particular focus on how to best account for the macromolecular signal contribution. A robust, short-TE PRESS protocol is presented, which allows reliable quantification, in vivo, of metabolite signals at 3T in human brain. Water suppression was adapted to the experimental conditions at 3T. Metabolite signal from the parietal white matter was quantified in the time domain using QUEST (jMRUI). The increased macromolecular signal contribution at short TE was dealt with by two approaches, based on either metabolite nulling or initial signal truncation. A detailed comparison of the two approaches was made. The first used a metabolite-nulled signal, measured either individually or averaged over different subjects. The second used the total signal, metabolites and macromolecules, from a single scan. The two approaches gave similar quantification results in terms of metabolite concentrations, but differed in their precision and the number of metabolites quantified reliably. With an average metabolite-nulled baseline, a set of seven metabolites could be reliably quantified in parietal white matter under these experimental conditions: N-acetylaspartate, myo-inositol, glucose, glutamate, glutathione, creatine and choline. When initial signal truncation was used, glucose was removed from this set. The short TE (10-11 ms) facilitated quantification of glutamate. The reliable quantification of N-acetylaspartyl glutamate at 3T proved very difficult. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:507 / 517
页数:11
相关论文
共 55 条
[1]
Single-voxel proton MRS of the human brain at 1.5T and 3.0T [J].
Barker, PB ;
Hearshen, DO ;
Boska, MD .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :765-769
[2]
ANALYSIS OF MACROMOLECULE RESONANCES IN H-1-NMR SPECTRA OF HUMAN BRAIN [J].
BEHAR, KL ;
ROTHMAN, DL ;
SPENCER, DD ;
PETROFF, OAC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :294-302
[3]
SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO [J].
BOTTOMLEY, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :333-348
[4]
CAVASILLA S, 1996, THESIS U CLAUDE BERN
[5]
Cramer-Rao bound expressions for parametric estimation of overlapping peaks: Influence of prior knowledge [J].
Cavassila, S ;
Deval, S ;
Huegen, C ;
van Ormondt, D ;
Graveron-Demilly, D .
JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (02) :311-320
[6]
T2 measurement and quantification of glutamate in human brain in vivo [J].
Choi, Changho ;
Coupland, Nicholas J. ;
Bhardwaj, Paramjit P. ;
Kalra, Sanjay ;
Casault, Colin A. ;
Reid, Kim ;
Allen, Peter S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :971-977
[7]
Brain glucose concentrations in patients with type 1 diabetes and hypoglycemia unawareness [J].
Criego, AB ;
Tkac, I ;
Kumar, A ;
Thomas, W ;
Gruetter, R ;
Seaquist, ER .
JOURNAL OF NEUROSCIENCE RESEARCH, 2005, 79 (1-2) :42-47
[8]
3 METHODS OF CALIBRATION IN QUANTITATIVE PROTON MR SPECTROSCOPY [J].
DANIELSEN, ER ;
MICHAELIS, T ;
ROSS, BD .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 106 (03) :287-291
[9]
ABSOLUTE QUANTITATION OF WATER AND METABOLITES IN THE HUMAN BRAIN .1. COMPARTMENTS AND WATER [J].
ERNST, T ;
KREIS, R ;
ROSS, BD .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 102 (01) :1-8
[10]
Elimination of artifacts in short echo time H-1 MR spectroscopy of the frontal lobe [J].
Ernst, T ;
Chang, L .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :462-468