Design and implementation of an automated partial volume correction in PET: Application to dopamine receptor quantification in the normal human striatum

被引:81
作者
Rousset, Olivier G. [1 ]
Collins, D. Louis [2 ]
Rahmim, Arman [1 ]
Wong, Dean F. [1 ,3 ,4 ,5 ]
机构
[1] Johns Hopkins Univ, Johns Hopkins Med Inst, Russell H Morgan Dept Radiol, Div Nucl Med,Sect High Resolut Brain PET Imaging, Baltimore, MD 21287 USA
[2] McGill Univ, Montreal Neurol Inst, McCornell Brain Imaging Ctr, Montreal, PQ, Canada
[3] Johns Hopkins Univ, Dept Psychiat, Baltimore, MD USA
[4] Johns Hopkins Univ, Dept Neurosci, Baltimore, MD USA
[5] Johns Hopkins Univ, Dept Environm Hlth Sci, Baltimore, MD 21205 USA
关键词
PET; partial-volume correction; 3D ROI; automatic algorithm; striatum;
D O I
10.2967/jnumed.107.048330
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The considerable effort and potential lack of reproducibility of human-driven PET quantification and partial volume correction (PVC) can be alleviated by use of atlas-based automatic analysis. The present study examined the application of a new algorithm designed to automatically define 3-dimensional regions of interest (ROIs) and their effect on dopamine receptor quantification in the normal human brain striatum, both without and with PVC. Methods: A total of 90 healthy volunteers (age range, 18-46 y) received a single injection of C-11-raclopride, and automatic segmentation of concomitant structural MR images was performed using a maximum-probability atlas in combination with a trained neural network. For each identified tissue segment considered homogeneous for the tracer (or volumes of interest [VOIs]), an a priori criterion based on minimum axial recovery coefficient (RCzmin = 50%, 75%, and 90%) was used to constrain the extent of each ROI. Results: With ROIs essentially overlapping the entire VOI volume (obtained with RCzmin = 50%), the binding potential (BPND) of C-11-raclopride was found to be around 2.2 for caudate and 2.9 for putamen, an underestimation by 35% and 28%, respectively, according to PVC values. At increased RCzmin, BPND estimates of C-11-raclopride were increased by 12% and 21% for caudate and 8% and 15% for putamen when the associated ROIs decreased to around 65% and 43% of total tissue volume (VOI) for caudate and 67% and 31% for putamen. After PVC, we observed relative increases in BPND variance of 12% for caudate and 20% for putamen, whereas estimated BPND values all increased to 3.4 for caudate and 4.0 for putamen, regardless of ROI size. Dopamine receptor concentrations appeared less heterogeneous in the normal human striatum after PVC than they did without PVC: the 25%-30% difference in BPND estimates observed between caudate and putamen remained significant after PVC but was reduced to slightly less than 20%. Furthermore, the results were comparable with those obtained with a manual method currently in use in our laboratory. Conclusion: The new algorithm allows for traditional PET data extraction and PVC in an entirely automatic fashion, thus avoiding labor-intensive analyses and potential intra- or interobserver variability. This study also offers the first, to our knowledge, large-scale application of PVC to dopamine D-2/D-3 receptor imaging with C-11-raclopride in humans.
引用
收藏
页码:1097 / 1106
页数:10
相关论文
共 33 条
  • [1] Ketamine does not decrease striatal dopamine D2 receptor binding in man
    Aalto, S
    Hirvonen, J
    Kajander, J
    Scheinin, H
    Någren, K
    Vilkman, H
    Gustafsson, L
    Syvälahti, E
    Hietala, J
    [J]. PSYCHOPHARMACOLOGY, 2002, 164 (04) : 401 - 406
  • [2] Atlas-based hippocampus segmentation in Alzheimer's disease and mild cognitive impairment
    Carmichael, OT
    Aizenstein, HA
    Davis, SW
    Becker, JT
    Thompson, PM
    Meltzer, CC
    Liu, YX
    [J]. NEUROIMAGE, 2005, 27 (04) : 979 - 990
  • [3] Automatic 3-D model-based neuroanatomical segmentation
    Collins, DL
    Holmes, CJ
    Peters, TM
    Evans, AC
    [J]. HUMAN BRAIN MAPPING, 1995, 3 (03) : 190 - 208
  • [4] Collins DL, 1999, LECT NOTES COMPUT SC, V1613, P210
  • [5] FULLY 3-DIMENSIONAL POSITRON EMISSION TOMOGRAPHY
    COLSHER, JG
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01) : 103 - 115
  • [6] Axial slice width in 3D PET: characterization and potential improvement with axial interleaving
    Daube-Witherspoon, ME
    Carson, RE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) : 921 - 928
  • [7] DEGRADO TR, 1994, J NUCL MED, V35, P1398
  • [8] Appearance-based segmentation of medial temporal lobe structures
    Duchesne, S
    Pruessner, JC
    Collins, DL
    [J]. NEUROIMAGE, 2002, 17 (02) : 515 - 531
  • [9] EVANS AC, 1993, J NUCL MED, V34, pP70
  • [10] Frouin V, 2002, J NUCL MED, V43, P1715