Transmission electron microscopy of intracellular particles of polyethylene from joint replacement prostheses: size distribution and cellular response

被引:26
作者
Benz, EB
Federman, M
Godleski, JJ
Bierbaum, BE
Thornhill, TS
Spector, M [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Orthopaed Surg, Boston, MA 02115 USA
[2] Beth Israel Deaconess Med Ctr, Dept Pathol, Boston, MA 02115 USA
[3] Harvard Univ, Sch Publ Hlth, Sch Med,Dept Pathol, Resp Biol Program,Brigham & Womens Hosp, Boston, MA 02115 USA
[4] New England Baptist Hosp, Boston, MA 02115 USA
关键词
D O I
10.1016/S0142-9612(01)00027-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objectives of this transmission electron microscopy study of peri-implant tissues retrieved at revision arthroplasty were to (1) determine the size distribution of intracellular polyethylene particles, and (2) assess the cellular response to phagocytosed polyethylene particles as revealed by the condition of the cellular organelles. The frequency distributions of intracellular polyethylene particle sizes for 15 cases of total hip replacement showed that more than 75% of the particles had lengths of less than 0.5 mum. More than 90% of the particles were less than 1.0 mum in size. In comparison, the frequency distribution for the particles in cells comprising tissue retrieved from three total knee replacement prostheses showed that only 43% of the particles were less than 0.5 mum in length and 72% were less than 1 mum in size. There was no statistically significant difference in the mean particle length between the specimens from the hip and knee patients. The majority of the cells containing polyethylene were without signs of degeneration. The cytoplasmic and nuclear membranes were intact. Several electron lucent voids which once contained polyethylene particles were seen surrounded by several healthy appearing mitochondria, which displayed sharp membranes and intact cristae. There were no signs of a cytotoxic response to polyethylene at the ultrastructural level. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2835 / 2842
页数:8
相关论文
共 34 条
  • [1] ISOLATION OF PREDOMINANTLY SUBMICRON-SIZED UHMWPE WEAR PARTICLES FROM PERIPROSTHETIC TISSUES
    CAMPBELL, P
    MA, S
    YEOM, B
    MCKELLOP, H
    SCHMALZRIED, TP
    AMSTUTZ, HC
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01): : 127 - 131
  • [2] RESPONSE OF 3 MURINE MACROPHAGE POPULATIONS TO PARTICULATE DEBRIS - BONE-RESORPTION IN ORGAN-CULTURES
    GLANT, TT
    JACOBS, JJ
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (05) : 720 - 731
  • [3] GLANT TT, 1993, J BONE MINER RES, V8, P1071
  • [4] THE SYNOVIAL-LIKE MEMBRANE AT THE BONE-CEMENT INTERFACE IN LOOSE TOTAL HIP REPLACEMENTS AND ITS PROPOSED ROLE IN BONE LYSIS
    GOLDRING, SR
    SCHILLER, AL
    ROELKE, M
    ROURKE, CM
    ONEILL, DA
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (05) : 575 - 584
  • [5] Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro
    Green, TR
    Fisher, J
    Stone, M
    Wroblewski, BM
    Ingham, E
    [J]. BIOMATERIALS, 1998, 19 (24) : 2297 - 2302
  • [6] Hirakawa K, 1996, J BIOMED MATER RES, V31, P257, DOI 10.1002/(SICI)1097-4636(199606)31:2<257::AID-JBM13>3.0.CO
  • [7] 2-I
  • [8] A RAT MODEL OF RESORPTION OF BONE AT THE CEMENT-BONE INTERFACE IN THE PRESENCE OF POLYETHYLENE WEAR PARTICLES
    HOWIE, DW
    VERNONROBERTS, B
    OAKESHOTT, R
    MANTHEY, B
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) : 257 - 263
  • [9] Kubo T, 1999, J BIOMED MATER RES, V45, P363, DOI 10.1002/(SICI)1097-4636(19990615)45:4<363::AID-JBM11>3.0.CO
  • [10] 2-3