Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms

被引:103
作者
Brecher, ME
Means, N
Jere, CS
Heath, D
Rothenberg, S
Stutzman, LC
机构
[1] Organon Teknika, Durham, NC USA
[2] Univ N Carolina, Chapel Hill, NC USA
关键词
D O I
10.1046/j.1537-2995.2001.41040477.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
BACKGROUND: Approximately 1 in 2000 platelet components are bacterially contaminated. The time to detection of 15 seeded organisms in platelets recovered from an automated culture system was studied. STUDY DESIGN AND METHODS: Isolates of Bacillus cereus, Bacillus subtilis, Candida albicans, Clostridium perfringens, Corynebacterium species, Enterobacter cloacae, Escherichia coli, Klebsiella oxytoca, Propionibacterium acnes, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens, Streptococcus pyogenes, and Streptococcus viridans were inoculated into Day 2 apheresis platelet components to obtain a final concentration of approximately 10 and 100 CFU per mt (2 units/organism). Each bag was sampled 10 times (20 mL/sample). Four mt of each sample was inoculated into standard aerobic and anaerobic bottles and into aerobic and anaerobic bottles containing charcoal; 2 mt was inoculated into pediatric aerobic bottles (so as to maintain a 1:10 ratio of sample to media) and 1 mt into thioglycollate broth. RESULTS: With the exception of P.acnes, all organisms were detected in a mean of 9.2 to 25.6 hours. A range of 10 serial dilutions in inoculating concentrations was associated with an overall 10.1-percent difference in detection time. A mean of 74.4 and 86.2 hours (100 and 10 CFU/ml inocula, respectively) was required for the detection of Fl acnes in anaerobic bottles. CONCLUSION: Bacteria thought to be clinically significant platelet contaminants can be detected in 9.2 to 25.6 hours when the starting concentration is approximately 10 to 100 CFU per mt. Fl acnes required considerably longer incubation times for detection (in either aerobic or anaerobic bottles). However, Fl acnes is of questionable clinical significance. Such a detection system could be used in either a blood collection center or a transfusion service to screen platelet concentrates for bacterial contamination. Such testing (with sterile sampling performed so as to maintain a closed-bag system) would be expected to save lives and might allow an extension of platelet storage.
引用
收藏
页码:477 / 482
页数:6
相关论文
共 28 条
[1]
*AM ASS BLOOD BANK, 1996, ASS B AM ASS BLOOD B, V966
[2]
ESCHERICHIA-COLI SEPSIS FROM CONTAMINATED PLATELET TRANSFUSION [J].
ARNOW, PM ;
WEISS, LM ;
WEIL, D ;
ROSEN, NR .
ARCHIVES OF INTERNAL MEDICINE, 1986, 146 (02) :321-324
[3]
Blajchman M. A., 1997, Transfusion (Bethesda), V37, p74S
[4]
TRANSFUSION-ASSOCIATED BACTERIAL SEPSIS - THE PHOENIX RISES YET AGAIN [J].
BLAJCHMAN, MA .
TRANSFUSION, 1994, 34 (11) :940-942
[5]
Growth of bacteria in inoculated platelets: implications for bacteria detection and the extension of platelet storage [J].
Brecher, ME ;
Holland, PV ;
Pineda, AA ;
Tegtmeier, GE ;
Yomtovian, R .
TRANSFUSION, 2000, 40 (11) :1308-1312
[6]
THE USE OF A CHEMILUMINESCENCE-LINKED UNIVERSAL BACTERIAL RIBOSOMAL-RNA GENE PROBE AND BLOOD-GAS ANALYSIS FOR THE RAPID DETECTION OF BACTERIAL-CONTAMINATION IN WHITE CELL-REDUCED AND NONREDUCED PLATELETS [J].
BRECHER, ME ;
BOOTHE, G ;
KERR, A .
TRANSFUSION, 1993, 33 (06) :450-457
[7]
PLATELET BACTERIAL-CONTAMINATION AND THE USE OF A CHEMILUMINESCENCE-LINKED UNIVERSAL BACTERIAL RIBOSOMAL-RNA GENE PROBE [J].
BRECHER, ME ;
HOGAN, JJ ;
BOOTHE, G ;
KERR, A ;
MCCLANNAN, L ;
JACOBS, MR ;
YOMTOVIAN, R ;
CHONGOKOLWATANA, V ;
TEGTMEIER, G ;
HENDERSON, S ;
PINEDA, A ;
HALLING, V ;
KEMPER, M ;
KURAMATO, K ;
HOLLAND, PV ;
LONGIARU, M .
TRANSFUSION, 1994, 34 (09) :750-755
[8]
DETECTION AND QUANTITATION OF BACTERIA IN PLATELET PRODUCTS STORED AT AMBIENT-TEMPERATURE [J].
BUCHHOLZ, DH ;
YOUNG, VM ;
FRIEDMAN, NR ;
REILLY, JA ;
MARDINEY, MR .
TRANSFUSION, 1973, 13 (05) :268-275
[9]
Cooper L, 1999, TRANSFUSION, V39, p119S
[10]
BACTERIAL CONTAMINATION OF PLATELET CONCENTRATES STORED AT 20 DEGREES C [J].
CUNNINGHAM, M ;
CASH, JD .
JOURNAL OF CLINICAL PATHOLOGY, 1973, 26 (06) :401-404