Surface plasmon resonance sensors for detection of chemical and biological species

被引:3402
作者
Homola, Jiri [1 ]
机构
[1] Inst Photon & Elect ASCR, Prague 18251 8, Czech Republic
关键词
D O I
10.1021/cr068107d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Over the past 5 years, more than 100 SPR biosensors for the detection of a variety of chemical and biological analytes were demonstrated. Most of these biosensors are based on prism coupling and angular or wavelength spectroscopy of surface plasmons. Commercial SPR systems have played an important role in the development of detection applications due to their increasing spread and the availability of special SPR platforms and kits dedicated to specific applications (e.g., Biacore Q for food analysis). Data collected in Tables 1-3 illustrate recent applications of SPR biosensors and achieved levels of performance. The performance figures should be compared with caution as performance of an SPR biosensor is a result of a multitude of factors (performance of optical platform, characteristics of the employed biorecognition element, suitability and degree of optimization of the immobilization method, detection format, and methodology), and thus low performance of one part of the biosensor (e.g., optical platform) can be compensated for by high performance of another component (e.g., biorecognition elements). Clearly, analytes implicated in food safety have received the most attention (Table 1). Bacterial pathogens such as E. coli and Salmonella were the most frequently targeted analytes. Detection limits below 102 bacteria/mL were reported. A great deal of research has been devoted to the development of SPR biosensors for other significant groups of analytes such as Staphylococcal enterotoxins (best demonstrated LODs < 1 ng/mL and antibiotics (best LODs < 1-10 ng/ mL depending on the substance). Several analytes have been detected also in complex food matrices. In the field of medical diagnostics (Table 2), the most attention has been paid to the development of SPR sensors for the detection of cancer markers (best LODs < 1-100 ng/mL) and antibodies (best LODs < 1-100 ng/mL). However, most of the detection experiments were performed in buffers rather than in clinical samples. The development of SPR biosensors for environmental monitoring (Table 3) has focused mainly on the detection of pesticides. The best LODs ranged from 1 to 100 pg/mL, depending on the analyte. Detection experiments were performed in buffers or real-world water samples. Conclusions: In the past, 5 years, SPR biosensor technology has made substantial advances in terms of both sensor hardware and biospecific coatings. SPR biosensors have been applied for the detection of a variety of chemical and biological analytes. We envision that the performance of SPR biosensor technology will continue to evolve and that advanced SPR sensor platforms combined with novel biospecific surfaces with high resistance to the nonspecific binding will lead to robust SPR biosensors enabling rapid, sensitive, and specific detection of chemical and biological analytes in complex samples in the field. These biosensors will benefit numerous important sectors such as medical diagnostics, environmental monitoring, and food safety and security. Abbreviations: ATR, attenuated total reflection; CCD, charge-coupled device; DNA, deoxyribonucleic acid; ELISA, enzyme-linked immunosorbent assay; LED, light-emitting diode; LOD, limit of detection; MALDI-TOF, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry; RIU, refractive index unit; RNA, ribonucleic acid; scFvs, single-chain antibody fragment; SAM, self-assembled monolayer; SP, surface plasmon; SPR, surface plasmon resonance; WDM, wavelength division multiplexing. © 2008 American Chemical Society.
引用
收藏
页码:462 / 493
页数:32
相关论文
共 320 条
[1]   Development of a biosensor-based method for detection and isotyping of antibody responses to adenoviral-based gene therapy vectors [J].
Abad, LW ;
Neumann, M ;
Tobias, L ;
Obenauer-Kutner, L ;
Jacobs, S ;
Cullen, C .
ANALYTICAL BIOCHEMISTRY, 2002, 310 (01) :107-113
[2]   Multiple surface plasmon spectroscopy for study of biomolecular systems [J].
Adam, P ;
Dostálek, J ;
Homola, J .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) :774-781
[3]   Biosensor based on surface plasmon interferometry independent on variations of liquid's refraction index [J].
Alieva, E ;
Konopsky, VN .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :90-97
[4]   Trends and challenges in biochemical sensors for clinical and environmental monitoring [J].
Andreescu, S ;
Sadik, OA .
PURE AND APPLIED CHEMISTRY, 2004, 76 (04) :861-878
[5]   Development and validation of screening and confirmatory methods for the detection of chloramphenicol and chloramphenicol glucuronide using SPR biosensor and liquid chromatography-tandem mass spectrometry [J].
Ashwin, HM ;
Stead, SL ;
Taylor, JC ;
Startin, JR ;
Richmond, SF ;
Homer, V ;
Bigwood, T ;
Sharman, M .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :103-108
[6]   Antibody-antigenic peptide interactions monitored by SPR and QCM-D -: A model for SPR detection of IA-2 autoantibodies in human serum [J].
Ayela, Cedric ;
Roquet, Francoise ;
Valera, Lionel ;
Granier, Claude ;
Nicu, Liviu ;
Pugniere, Martine .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :3113-3119
[7]   Biosensors for environmental pollutants and food contaminants [J].
Baeumner, AJ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :434-445
[8]   Induced fit of an epitope peptide to a monoclonal antibody probed with a novel parallel surface plasmon resonance assay [J].
Baggio, R ;
Carven, GJ ;
Chiulli, A ;
Palmer, M ;
Stern, LJ ;
Arenas, JE .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2005, 280 (06) :4188-4194
[9]   Lytic phage as a specific and selective probe for detection of Staphylococcus aureus -: A surface plasmon resonance spectroscopic study [J].
Balasubramanian, Shankar ;
Sorokulova, Iryna B. ;
Vodyanoy, Vitaly J. ;
Simonian, Aleksandr L. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :948-955
[10]   Optical microarray biosensing techniques [J].
Bally, Marta ;
Halter, Martin ;
Voeroes, Janos ;
Grandin, H. Michelle .
SURFACE AND INTERFACE ANALYSIS, 2006, 38 (11) :1442-1458