Modified Soft-Switched Three-Phase Three-Level DC-DC Converter for High-Power Applications Having Extended Duty Cycle Range

被引:41
作者
Ghodke, Dharmraj V. [1 ]
Chatterjee, Kishore [2 ]
Fernandes, B. G. [2 ]
机构
[1] Raja Ramanna Ctr Adv Technol, Proton Linac & Superconducting Cavities Div, Indore 452013, Madhya Pradesh, India
[2] Indian Inst Technol, Dept Elect Engn, Bombay 400076, Maharashtra, India
关键词
High-power dc-to-dc converter; soft switching; tapped-inductor filter; three-phase three-level (TPTL); zero-voltage zero-current switching; DC/DC CONVERTER; VOLTAGE;
D O I
10.1109/TIE.2011.2171169
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A three-phase three-level dc-to-dc phase-shifted pulsewidth-modulation (PSPWM) converter which is reported in the literature for high-power and high-input-voltage applications is based on a three-phase three-wire configuration. However, the controllable duty cycle range of the aforementioned converter is 0-2 pi/3. Therefore, to obtain the rated voltage, the converter needs to be overrated by 33%. In order to overcome this problem, a modified topology of the three-level dc-to-dc PSPWM converter based on a three-phase four-wire configuration is proposed. The soft switching of devices is achieved by using a tapped filter inductor. The output voltage is controlled by incorporating PSPWM. The clocked gate signals of each leg are phase shifted by 2 pi/3 from each other. Major features of the converter include the following: 1) The outer two switches of each leg are operating as zero-voltage switch; 2) the inner two switches of each leg are operating as zero-current switch; and 3) this is achieved without involving any extra passive or active components. Realization of the secondary output filter by having a tapped inductor leads to considerable reduction in circulating current flow during a freewheeling period and results in appreciable mitigation in conduction losses. In order to obtain the behavioral and performance characteristics of the converter topology, analytical and simulation studies are carried out, and the viability of the scheme is ascertained through detailed experimental studies.
引用
收藏
页码:3362 / 3372
页数:11
相关论文
共 27 条
[1]   Snubberless Bidirectional DC-DC Converter With New CLLC Resonant Tank Featuring Minimized Switching Loss [J].
Chen, Wei ;
Rong, Ping ;
Lu, Zhengyu .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (09) :3075-3086
[2]   Soft-Switching PS-PWM DC-DC Converter for Full-Load Range Applications [J].
Dudrik, Jaroslav ;
Trip, Nistor-Daniel .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) :2807-2814
[3]   Three-phase three level, soft switched, phase shifted PWM DC-DC converter for high power applications [J].
Ghodke, Dharmraj V. ;
Chatterjee, Kishore ;
Fernandes, B. G. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) :1214-1227
[4]  
Hamada S., 1993, Fifth European Conference on Power Electronics and Applications (Conf. Publ. No.377), P130
[5]   Three-Level Bidirectional Converter for Fuel-Cell/Battery Hybrid Power System [J].
Jin, Ke ;
Yang, Mengxiong ;
Ruan, Xinbo ;
Xu, Min .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (06) :1976-1986
[6]   Integrated Magnetic Self-Driven ZVS Nonisolated Full-Bridge Converter [J].
Jin, Ke ;
Sun, Yi ;
Xu, Ming ;
Sterk, Douglas ;
Lee, Fred C. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (05) :1615-1623
[7]  
Kim ES, 2002, PCC-OSAKA 2002: PROCEEDINGS OF THE POWER CONVERSION CONFERENCE-OSAKA 2002, VOLS I - III, P115, DOI 10.1109/PCC.2002.998533
[8]  
Kim ES, 2001, APPL POWER ELECT CO, P980, DOI 10.1109/APEC.2001.912486
[9]   Zero-Voltage- and Zero-Current-Switching Full-Bridge Converter With Secondary Resonance [J].
Kim, Eung-Ho ;
Kwon, Bong-Hwan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (03) :1017-1025
[10]   Recent Advances and Industrial Applications of Multilevel Converters [J].
Kouro, Samir ;
Malinowski, Mariusz ;
Gopakumar, K. ;
Pou, Josep ;
Franquelo, Leopoldo G. ;
Wu, Bin ;
Rodriguez, Jose ;
Perez, Marcelo A. ;
Leon, Jose I. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) :2553-2580