1φ 3W grid-connection PV power inverter with partial active power filter

被引:40
作者
Wu, TF [1 ]
Shen, CL [1 ]
Chang, CH [1 ]
Chiu, JY [1 ]
机构
[1] Natl Chung Cheng Univ, Dept Elect Engn, Chiayi, Taiwan
关键词
D O I
10.1109/TAES.2003.1207271
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This paper presents a single-phase three-wire (1 phi 3W) grid-connection photovoltaic (PV) power inverter with a feature of partial active power filter (PAPF), which can not only deal with PV power but filter current harmonics and improve power factor. Once the processed power exceeds the switch ratings, the inverter can reduce its output reactive power and harmonic power, while still supplying the maximum real power generated by the PV arrays. In derivation of control laws, a limit circle is defined to confine the output power of the inverter. To determine the power that the inverter can process, instantaneous reactive power of a 16 3W system is defined and used to calculate reactive power, which can avoid complex detections of phase angle and magnitude of the fundamental component of a nonlinear load current. Simulation results and experimental measurements have verified the proposed algorithm and the feasibility of the inverter.
引用
收藏
页码:635 / 646
页数:12
相关论文
共 12 条
[1]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[2]  
BAHU SS, 1996, P POW EL SPEC C JAN, V1, P101
[3]  
Cheng L, 1997, IEEE POWER ELECTRON, P279, DOI 10.1109/PESC.1997.616737
[4]   Residential photovoltaic energy storage system [J].
Chiang, SJ ;
Chang, KT ;
Yen, CY .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (03) :385-394
[5]  
Hirachi K, 1996, IEEE IND ELEC, P1693, DOI 10.1109/IECON.1996.570669
[6]  
KIKUCHI N, 1999, P IECON 99, V1, P385
[7]  
KIM HS, 1994, IEEE PHOT SPEC CONF, P1069, DOI 10.1109/WCPEC.1994.520146
[8]   A bifunctional utility connected photovoltaic system with power factor correction and UPS facility [J].
Kim, S ;
Yoo, G ;
Song, J .
CONFERENCE RECORD OF THE TWENTY FIFTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 1996, 1996, :1363-1368
[9]  
Komatsu Y, 1997, 1997 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, PROCEEDINGS, VOLS 1 AND 2, P839, DOI 10.1109/PEDS.1997.627504
[10]   Novel maximum-power-point-tracking controller for photovoltaic energy conversion system [J].
Kuo, YC ;