In vitro toxicity and mutagenicity of CoCrMo and Ti6Al wear particles

被引:25
作者
Katzer, A
Hockertz, S
Buchhorn, GH
Loehr, JF
机构
[1] ENDO Klin, D-22767 Hamburg, Germany
[2] Unweltmed Hamburg EV, Inst Toxicol, Univ Krankenhaus Eppendorf, D-22527 Hamburg, Germany
[3] Klinikum Univ Gottingen, Abt Orthopad, Lab Biomat, D-37075 Gottingen, Germany
关键词
endoprosthesis metallic wear particles; toxicity; mutagenicity; carcinogenicity; endoprosthesis loosening;
D O I
10.1016/S0300-483X(03)00147-1
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Contact of wear particles with body fluids can result in widespread dissemination of extractable constituents from joint implants. The ann of this in vitro study is to clarify whether there is a mutagenic and/or carcinogenic risk from CoCrMo and Ti6Al wear particles. Particles of a representative size were produced by fretting; toxicity and mutagenicity were investigated using the salmonella/microsome test according to AMES and the V79-HGPRT Test (Chinese Hamster Fibroblasts). To obtain the greatest possible elution of all constituents the metallic wear particles were extracted with dimethylsulfoxyd and water and the resulting eluates mixed together. Neither the bacterial assay nor the mammalian cell system after repeated test series under standardised conditions produced evidence of a toxic or mutagenic effect in the concentration range under study. It is therefore not to be expected that CoCrMo or Ti6Al alloys initiate carcinogenesis in the human organism. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:145 / 154
页数:10
相关论文
共 34 条
[1]   SINUS HISTIOCYTOSIS OF PELVIC LYMPH-NODES AFTER HIP-REPLACEMENT - A HISTIOCYTIC PROLIFERATION INDUCED BY COBALT-CHROMIUM AND TITANIUM [J].
ALBORESSAAVEDRA, J ;
VUITCH, F ;
DELGADO, R ;
WILEY, E ;
HAGLER, H .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1994, 18 (01) :83-90
[2]   METHODS FOR DETECTING CARCINOGENS AND MUTAGENS WITH SALMONELLA-MAMMALIAN-MICROSOME MUTAGENICITY TEST [J].
AMES, BN ;
MCCANN, J ;
YAMASAKI, E .
MUTATION RESEARCH, 1975, 31 (06) :347-363
[3]  
*ASTM, 1987, STAND PRACT DIR CONT, P323
[4]   CHROMIUM CONCENTRATIONS IN SERUM, BLOOD CLOT AND URINE FROM PATIENTS FOLLOWING TOTAL HIP-ARTHROPLASTY [J].
BARTOLOZZI, A ;
BLACK, J .
BIOMATERIALS, 1985, 6 (01) :2-8
[5]  
BETTS F, 1992, CLIN ORTHOP RELAT R, P75
[6]   DOES CORROSION MATTER [J].
BLACK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :517-520
[7]  
BRIEN WW, 1992, CLIN ORTHOP RELAT R, P66
[8]   OSTEOGENIC-SARCOMA ARISING IN THE AREA OF A TOTAL HIP-REPLACEMENT - A CASE-REPORT [J].
BRIEN, WW ;
SALVATI, EA ;
HEALEY, JH ;
BANSAL, M ;
GHELMAN, B ;
BETTS, F .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07) :1097-1099
[9]   Metal-on-metal bearing with THA and chronic renal failure. [J].
Brodner, V ;
Grohs, JG ;
Bitzan, P ;
Meisinger, V ;
Kovarik, J ;
Kotz, R .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (05) :425-429
[10]   EXCESSIVE METAL RELEASE DUE TO LOOSENING AND FRETTING OF SINTERED PARTICLES ON POROUS-COATED HIP PROSTHESES - REPORT OF 2 CASES [J].
BUCHERT, PK ;
VAUGHN, BK ;
MALLORY, TH ;
ENGH, CA ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (04) :606-609