The intrinsic redox reactions of polyamic acid derivatives and their application in hydrogen peroxide sensor

被引:38
作者
Hua, Mu-Yi [1 ]
Chen, Hsiao-Chien [1 ]
Chuang, Cheng-Keng [2 ,6 ]
Tsai, Rung-Ywan [3 ,5 ]
Jeng, Jyh-Long [4 ]
Yang, Hung-Wei [1 ]
Chern, Yaw-Terng [4 ]
机构
[1] Chang Gung Univ, Biomed Ctr, Biosensor Grp, Tao Yuan 33302, Taiwan
[2] Chang Gung Univ, Dept Urol, Coll Med, Taipei 33305, Taiwan
[3] Ind Technol Res Inst, Elect Res Lab, Hsinchu 31040, Taiwan
[4] Natl Taiwan Univ Sci & Technol, Dept Chem Engn, Taipei 10607, Taiwan
[5] Ind Technol Res Inst, Optoelect Res Lab, Hsinchu 31040, Taiwan
[6] Mem Hosp, Taipei 33305, Taiwan
关键词
Polyamic acid; Hydrogen peroxide; Enzyme-free; Biosensor; Benzothiazole; Benzoxazole; DIRECT ELECTROCHEMISTRY; HORSERADISH-PEROXIDASE; GLUCOSE; CARBON; H2O2; IMMOBILIZATION; NANOPARTICLES; OXIDASE; COPPER; FILMS;
D O I
10.1016/j.biomaterials.2011.03.051
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyamic acids (PAAs) containing benzothiazole (BT) and benzoxazole (BO) pendent groups (PAA-BT and PAA-BO, respectively) which possessed electroactivity were synthesized successfully. The addition of H2O2 chemically oxidized the intrinsic carboxylic acid groups of PAA to form peroxy acid groups, and the peroxy acid further oxidized the electroactive sites of BT and BO to form N-oxides. The N-oxides could be reverted to their original form by electrochemical reduction, thus increasing the electrochemical reductive current. Based on this mechanism, enzyme-free hydrogen peroxide (H2O2) biosensors were prepared by modifying gold electrodes with the PAA derivatives (PAA-BT/Au and PAA-BO/Au. respectively). These biosensors had rapid response times (3.9-5.2 s) and high selectivity and sensitivity (280.6 -311.2 mu A/mM-cm(2)). A comparison of the PAA-BT/Au and PAA-BO/Au electrodes with electrodes prepared using polyamide-BT or polyamide-BO (i.e., lacking the carboxylic acid groups) confirmed the mechanism by which PAA derivatives detect H2O2. Modifying the surface morphology of the electrode from a planar to a three-dimensional (3D) configuration enhanced the performance of the PAA-BO/Au electrode. The sensitivity of the 3D-PAA-BO/Au electrode was 1394.9 mu A/mM-cm(2), similar to 4.5 times higher than that of the planar electrode. The detection limit was also enhanced from 5.0 to 1.43 mu M. The biosensor was used analytically to detect and measure H2O2 in urine samples collected from healthy individuals and patients suffering from noninvasive bladder cancer. The results were promising and comparable to that measured by a classical HPLC method, which verified the developed biosensor had a potential to provide a usefully analytical approach for bladder cancer. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4885 / 4895
页数:11
相关论文
共 40 条
[1]   New nanostructured TiO2 for direct electrochemistry and glucose sensor applications [J].
Bao, Shu-Juan ;
Li, Chang Ming ;
Zang, Jian-Feng ;
Cui, Xiao-Qiang ;
Qiao, Yan ;
Guo, Jun .
ADVANCED FUNCTIONAL MATERIALS, 2008, 18 (04) :591-599
[2]   In situ growth of copper sulfide nanoparticles on ordered mesoporous carbon and their application as nonenzymatic amperometric sensor of hydrogen peroxide [J].
Bo, Xiangjie ;
Bai, Jing ;
Wang, Lixia ;
Guo, Liping .
TALANTA, 2010, 81 (1-2) :339-345
[3]   Pt nanoparticle-based highly sensitive platform for the enzyme-free amperometric sensing of H2O2 [J].
Chakraborty, Sudip ;
Raj, C. Retna .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) :3264-3268
[4]   Conformation of Polyimide Backbone Structures for Determination of the Pretilt Angle of Liquid Crystals [J].
Chern, Yaw-Terng ;
Ju, Ming-Hung .
MACROMOLECULES, 2009, 42 (01) :169-179
[5]   Low Dielectric Constant and High Organosolubility of Novel Polyimide Derived from Unsymmetric 1,4-Bis(4-aminophenoxy)-2,6-di-tert-butylbenzene [J].
Chern, Yaw-Terng ;
Tsai, Jeng-Yu .
MACROMOLECULES, 2008, 41 (24) :9556-9564
[6]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[7]  
Donnici CL, 1998, J BRAZIL CHEM SOC, V9, P455
[8]   Enhancing the electrochemical response of myoglobin with carbon nanotube electrodes [J].
Esplandiu, M. J. ;
Pacios, M. ;
Cyganek, L. ;
Bartroli, J. ;
del Valle, M. .
NANOTECHNOLOGY, 2009, 20 (35)
[9]  
Ghosh M.K., 1996, Polyimides: Fundamentals and Applications
[10]   FERROCENE AND FERRICENIUM ION AS VERSATILE PHOTOMETRIC TITRANTS OF H2O2 AND D-GLUCOSE IN THE PRESENCE OF PEROXIDASE AND GLUCOSE-OXIDASE - A FERROCENE-PEROXIDASE STAIRWAY [J].
GORAL, VN ;
NELEN, MI ;
RYABOV, AD .
ANALYTICAL LETTERS, 1995, 28 (12) :2139-2148