Constrained customization of non-coplanar beam orientations in radiotherapy of brain tumours

被引:39
作者
Rowbottom, CG [1 ]
Oldham, M
Webb, S
机构
[1] Inst Canc Res, Joint Dept Phys, Downs Rd, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Downs Rd, Sutton SM2 5PT, Surrey, England
关键词
D O I
10.1088/0031-9155/44/2/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A methodology for the constrained customization of non-coplanar beam orientations in radiotherapy treatment planning has been developed and tested on a cohort of five patients with tumours of the brain. The methodology employed a combination of single and multibeam cost functions to produce customized beam orientations. The single-beam cost function was used to reduce the search space for the multibeam cost function, which was minimized using a fast simulated annealing algorithm. The scheme aims to produce well-spaced, customized beam orientations for each patient that produce low dose to organs at risk (OARs). The customized plans were compared with standard plans containing the number and orientation of beams chosen by a human planner. The beam orientation constraint-customized plans employed the same number of treatment beams as the standard plan but with beam orientations chosen by the constrained-customization scheme. Improvements from beam orientation constraint-customization were studied in isolation by customizing the beam weights of both plans using a dose-based downhill simplex algorithm. The results show that beam orientation constraint-customization reduced the maximum dose to the orbits by an average of 18.8 (+/-3.8, 1SD)% and to the optic nerves by 11.4 (+/-4.8, 1SD)% with no degradation of the planning target volume (PTV) dose distribution. The mean doses, averaged over the patient cohort, were reduced by 4.2 (+/-1.1, ISD)% and 12.4 (+/-3.1, ISD)% for the orbits and optic nerves respectively. In conclusion, the beam orientation constraint-customization can reduce the dose to OARs, for few-beam treatment plans, when compared with standard treatment plans developed by a human planner.
引用
收藏
页码:383 / 399
页数:17
相关论文
共 39 条
[1]  
[Anonymous], P 11 INT C US COMP R
[2]  
[Anonymous], RAD RES S
[3]   Methods for transferring patient and plan data between radiotherapy treatment planning systems [J].
Bedford, JL ;
Oldham, M ;
Hoess, A ;
Evans, PM ;
Shentall, GS ;
Webb, S .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (835) :740-749
[4]  
Bortfeld T, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P1
[5]   OPTIMIZATION OF BEAM ORIENTATIONS IN RADIATION-THERAPY - SOME THEORETICAL CONSIDERATIONS [J].
BORTFELD, T ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02) :291-304
[6]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[7]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[8]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[9]  
Carol MP, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P317
[10]   THE USE OF BEAM EYE VIEW VOLUMETRICS IN THE SELECTION OF NONCOPLANAR RADIATION PORTALS [J].
CHEN, GTY ;
SPELBRING, DR ;
PELIZZARI, CA ;
BALTER, JM ;
MYRIANTHOPOULOS, LC ;
VIJAYAKUMAR, S ;
HALPERN, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (01) :153-163