Dynamic characteristics of a R-410A split air-conditioning system

被引:50
作者
Kim, MH [1 ]
Bullard, CW [1 ]
机构
[1] Univ Illinois, Dept Mech & Ind Engn, Urbana, IL 61801 USA
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2001年 / 24卷 / 07期
关键词
air conditioining; air conditioner; refrigerant; R410A; capillary; operation; performance; shut-down; start-up;
D O I
10.1016/S0140-7007(00)00088-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents experimental results on the shut-down and start-up characteristics of a residential split system R410A air-conditioner with a capillary tube. During shut-down, the transient characteristics are evaluated by measuring the high and low side pressures and temperatures of the system. The dynamic behavior of the system after start-up is also investigated at the standard cooling capacity rating condition of which the dry and wet bulb temperatures for the indoor and outdoor are 27/19.5 and 35/24 degreesC, respectively. All experiments are performed in a psychrometric calorimeter. The cooling capacity, power consumption, dehumidification capacity and cycle characteristics after start-up are analyzed. The test results show that the cooling capacity and the coefficient of performance (COP) after start-up can be expressed as the combination of two exponential functions of time, approaching the cooling capacity of steady-state. (C) 2001 Elsevier Science Ltd and IIR. All rights reserved.
引用
收藏
页码:652 / 659
页数:8
相关论文
共 21 条
[1]
[Anonymous], ASHRAE T
[2]
[Anonymous], ASHRAE T
[3]
*ASHRAE, 1987, ANSI ASHRAE 41 2 198
[4]
BALTH ML, 1988, INT J REFRIG, V11, P298
[5]
BURNS LD, 1996, INT S HCFC ALT REFR, P61
[6]
Chi J., 1982, INT J REFRIG, V5, P176, DOI 10.1016/0140-7007(82)90099-8
[7]
DHAR M, 1978, THESIS PURDUE U
[8]
GOLDSCHMIDT VW, 1980, ASHRAE T, V86, P368
[9]
JAKOBSEN A, 1995, THESIS TU DENMARK, P77
[10]
JUDGE JF, 1995, P ASME, P1