Effect of pulse delay time on a pre-ablation dual-pulse LIBS plasma

被引:132
作者
Stratis, DN [1 ]
Eland, KL [1 ]
Angel, SM [1 ]
机构
[1] Univ S Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
关键词
LIBS; LIPS; dual-pulse LIBS; pre-ablation spark; laser-induced breakdown spectroscopy; laser ablation; plasma temperature; plasma imaging; laser-induced plasma; time-resolved imaging; LCTF;
D O I
10.1366/0003702011953649
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we investigate the effect of dual-pulse timing on material ablation, plasma temperature, and plasma size for pre-ablation spark dual-pulse laser-induced breakdown spectroscopy (LIBS). Although the plasma temperature increases for dual-pulse excitation, the signal enhancement is most easily attributed to increased sample ablation. Plasma images show that the magnitude of the enhancement can be affected by the collection optic and by the collection geometry. Enhancements calculated using the total integrated intensity of the plasma are comparable to those measured using fiber-optic collection.
引用
收藏
页码:1297 / 1303
页数:7
相关论文
共 32 条
[1]   RAPID SURVEY ANALYSIS OF POLYMERIC MATERIALS BY LASER-INDUCED PLASMA EMISSION-SPECTROMETRY [J].
ANDERSON, DR ;
MCLEOD, CW ;
SMITH, TA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (02) :67-72
[2]   LIBS using dual- and ultra-short laser pulses [J].
Angel, SM ;
Stratis, DN ;
Eland, KL ;
Lai, TS ;
Berg, MA ;
Gold, DM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (3-4) :320-327
[3]   Pigment identification in painted artworks: A dual analytical approach employing laser-induced breakdown spectroscopy and Raman microscopy [J].
Burgio, L ;
Clark, RJH ;
Stratoudaki, T ;
Doulgeridis, M ;
Anglos, D .
APPLIED SPECTROSCOPY, 2000, 54 (04) :463-469
[4]   Battery powered laser-induced plasma spectrometer for elemental determinations [J].
Castle, BC ;
Knight, AK ;
Visser, K ;
Smith, BW ;
Winefordner, JD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (07) :589-595
[5]   SPECTROCHEMICAL ANALYSIS OF LIQUIDS USING THE LASER SPARK [J].
CREMERS, DA ;
RADZIEMSKI, LJ ;
LOREE, TR .
APPLIED SPECTROSCOPY, 1984, 38 (05) :721-729
[6]   Some comparisons of LIBS measurements using nanosecond and picosecond laser pulses [J].
Eland, KL ;
Stratis, DN ;
Lai, TS ;
Berg, MA ;
Goode, SR ;
Angel, SM .
APPLIED SPECTROSCOPY, 2001, 55 (03) :279-285
[7]   The development of a dual-pulse fiber-optic LIBS probe for in-situ elemental analyses [J].
Eland, KL ;
Stratis, DN ;
Carter, JC ;
Angel, SM .
ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES II, 1999, 3853 :288-294
[8]   ELECTRON-TEMPERATURE AND DENSITY PROFILES OF EXCIMER LASER-INDUCED PLASMAS [J].
GRANT, KJ ;
PAUL, GL .
APPLIED SPECTROSCOPY, 1990, 44 (08) :1349-1354
[9]   Characterization of laser-induced breakdown spectroscopy (LIBS) for application to space exploration [J].
Knight, AK ;
Scherbarth, NL ;
Cremers, DA ;
Ferris, MJ .
APPLIED SPECTROSCOPY, 2000, 54 (03) :331-340
[10]   Spectroscopic analysis of fire suppressants and refrigerants by laser-induced breakdown spectroscopy [J].
Lancaster, ED ;
McNesby, KL ;
Daniel, RG ;
Miziolek, AW .
APPLIED OPTICS, 1999, 38 (09) :1476-1480