Effect of column flow rate and sample injection mode on compound-independent calibration using gas chromatography with atomic emission detection

被引:17
作者
Stevens, NA [1 ]
Borgerding, MF [1 ]
机构
[1] Virginia Tech, Dept Chem, Blacksburg, VA 24061 USA
关键词
D O I
10.1021/ac9804386
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Compound-independent calibration (CIC) is a theoretical concept in which a single compound is used to quantitate other compounds within a sample. Gas chromatography with atomic emission detection (AED) is one technique in which CIC can theoretically be applied. Reports are present in the literature, however, that both support CIC and indicate dependence of the AED response on compound structure. In this investigation, the effects of two gas chromatographic parameters (injection mode and column now rate) on the atomic emission detector elemental response factor (ERF, peak area per nanogram of element injected) were studied. Seven compounds containing various nitrogen functional groups and three detection wavelengths (C at 179 nm, H at 486 nm, and N at 174 nm) were used in this work to explore CIC with GC-AED, When on-column injection was used, the calibration plots for the seven compounds fell on the same line (R = 0.9995), indicating that CIC was possible. However, when splitless injection was employed, an apparent compound dependence of the AED response was observed due to discrimination at the injector. The now rate dependence of AED response was demonstrated through studies performed with on-column injection and constant now rates of 1.0, 2.8, and 5.0 mL/min. All three conditions produce compound-independent response, yet the average ERFs varied with the different now rates. When a constant head pressure of 30 psi was used, the ERFs for the seven compounds became more variable due to the change in now rate during a temperature-programmed chromatographic experiment. Thus, the experimental parameters of injection mode and column now rate must be considered in order to prevent apparent compound dependence of AED response.
引用
收藏
页码:4223 / 4227
页数:5
相关论文
共 11 条
[1]   THE ATOMIC-EMISSION DETECTOR IN GAS-CHROMATOGRAPHIC TRACE ANALYSIS - SOME STUDIES ON THE PERFORMANCE AND APPLICATIONS [J].
ANDERSSON, JT ;
SCHMID, B .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (04) :403-409
[2]  
KLEE MS, 1990, GC INLETS INTRO, P47
[3]   APPLICATION OF A MICROWAVE-INDUCED PLASMA ATOMIC EMISSION DETECTOR FOR QUANTIFICATION OF HALOGENATED COMPOUNDS BY GAS-CHROMATOGRAPHY [J].
KOVACIC, N ;
RAMUS, TL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :999-1005
[4]  
MCNAIR HM, 1993, LC GC-MAG SEP SCI, V11, P794
[5]   DETERMINATION OF SULFUR-CONTAINING AND CHLORINE-CONTAINING COMPOUNDS USING CAPILLARY GAS-CHROMATOGRAPHY AND ATOMIC EMISSION DETECTION [J].
PEDERSENBJERGAARD, S ;
ASP, TN ;
GREIBROKK, T .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :87-92
[6]  
Sandra P., 1989, HIGH RESOLUTION GAS
[7]   CHARACTERIZATION OF A COMPUTERIZED PHOTODIODE ARRAY SPECTROMETER FOR GAS-CHROMATOGRAPHY ATOMIC EMISSION-SPECTROMETRY [J].
SULLIVAN, JJ ;
QUIMBY, BD .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1034-1043
[8]  
SULLIVAN JJ, 1989, HRC-J HIGH RES CHROM, V12, P282
[9]  
SZELEWSKI MJ, 228382 HEWL PACK APP
[10]   OPTIMIZATION OF MICROWAVE-INDUCED PLASMA AS AN ELEMENT-SELECTIVE DETECTOR FOR NON-METALS [J].
VANDALEN, JPJ ;
DELEZENNECOULANDER, PA ;
DEGALAN, L .
ANALYTICA CHIMICA ACTA, 1977, 94 (01) :1-19