Background: The relatively limited variety of sur faces and geometries challenged in current sporicidal resting reduces the predictive value of these analyses when extrapolated to the wide variety of medical devices. The unknown spore load being challenged and the qualitative nature (growth/no growth) of those tests further prevent precise comparison among liquid chemical disinfectants. Hence, the relative activity of different chemical substances has not been clearly established, hindering selection of the best agent for each clinical situation. Methods: A micromethod was developed io assess sporicidal activity against Bacillus subtilis spores deposited on three different medical devices: carbon-steel dental burs, silicone-rubber medical catheters, and titanium-alloy dental abutmeat screws. The spore load on each device and the recovery after three analytical steps were quantitatively assessed with spores radiolabeled with carbon 14 methionine. Results: The killing of 2 to 7 x 10(6) spores loaded on three different devices and exposed to glutaraldehyde, formaldehyde, copper ascorbate, hydrogen peroxide, peracetic acid, sodium hypochlorite, or phenol for 30 minutes at 20 degrees C ranged from a 10(3)-fold decrease For 10% hydrogen peroxide to zero decrease for 5% phenol. Our results suggest that the nature of the surface being challenged may affect the sporicidal activity of some chemical agents. Conclusion: The quantitative data presented allow comparison of the sporicidal effect of different liquid chemical agents. These findings may help prevent an overestimation of sporicidal activity and possible transmission of pathogens from the surface of improperly decontaminated medical devices.
引用
收藏
页码:364 / 371
页数:8
相关论文
共 24 条
[1]  
[Anonymous], 1991, DISINFECTION STERILI
[2]  
BELOIAN A, 1987, CHEM GERMICIDES HLTH, P132
[3]  
BELOIAN A, 1990, AOAC OFFICIAL METHOD, P133
[4]  
DANIELSON JW, 1993, J AOAC INT, V76, P355
[5]  
FAVERO MS, 1985, MANUAL CLIN MICROBIO, P129
[6]  
FORSYTH MP, 1975, DEV IND MICROBIOL, V16, P37
[7]  
GORSCHEL DHM, 1991, J HOSP INFECT A, V18, P274
[8]  
KELSEY J C, 1965, Mon Bull Minist Health Public Health Lab Serv, V24, P152
[9]   MEDIUM-DEPENDENT ALTERATION OF LYSINE TRANSFER RIBONUCLEIC ACID IN SPORULATING BACILLUS SUBTILIS CELLS [J].
LAZZARIN.RA ;
SANTANGE.E .
JOURNAL OF BACTERIOLOGY, 1967, 94 (01) :125-&
[10]  
MILLER BM, 1986, LAB SAFETY PRINCIPLE, V56