Advantages of external accumulation for electron capture dissociation in Fourier transform mass spectrometry

被引:93
作者
Haselmann, KF
Budnik, BA
Olsen, JV
Nielsen, ML
Reis, CA
Clausen, H
Johnsen, AH
Zubarev, RA
机构
[1] Univ So Denmark, Dept Chem, DK-5230 Odense M, Denmark
[2] Univ Copenhagen, Sch Dent, Copenhagen, Denmark
[3] Rigshosp, DK-2100 Copenhagen, Denmark
关键词
D O I
10.1021/ac0015523
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combination of external accumulation (XA) with electron capture dissociation (ECD) improves the electron capture efficiency, shortens the analysis time, and allows for rapid integration of multiple scans in Fourier transform mass spectrometry, This improves the signal-to-noise ratio and increases the number of detected products, including structurally important MS3 fragments. With XA-ECD, the range of the labile species amenable to ECD is significantly extended. Examples include the first-time determination of the positions of six GalNAc groups in a 60-residue peptide, five sialic acid and six O-linked GalNAc groups in a 25-residue peptide, and the sulfate group position in a Ii-residue peptide. Even weakly bound supramolecular aggregates, including nonspecific peptide complexes, can be analyzed with XA-ECD, Preliminary results are reported on high-rate XA-ECD that uses an indirectly heated dispenser cathode as an electron source. This shortens the irradiation time to greater than or equal to1 ms and increases the acquisition rate to 3 scans/s, an improvement by a factor of 10-100.
引用
收藏
页码:2998 / 3005
页数:8
相关论文
共 29 条
[1]  
BENNETT EP, UNPUB J BIOL CHEM
[2]   Mechanistic studies of multipole storage assisted dissociation [J].
Håkansson, K ;
Axelsson, J ;
Palmblad, M ;
Håkansson, P .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (03) :210-217
[3]  
Haselmann KF, 2000, RAPID COMMUN MASS SP, V14, P2242, DOI 10.1002/1097-0231(20001215)14:23<2242::AID-RCM158>3.0.CO
[4]  
2-O
[5]  
HASELMANN KF, UNPUB
[6]   ELECTRON-BEAM POTENTIAL DEPRESSION AS AN ION-TRAP IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
HENDRICKSON, CL ;
HADJARAB, F ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 141 (02) :161-170
[7]  
Hofstadler SA, 1999, RAPID COMMUN MASS SP, V13, P1971, DOI 10.1002/(SICI)1097-0231(19991030)13:20<1971::AID-RCM740>3.0.CO
[8]  
2-D
[9]   Activated ion electron capture dissociation for mass spectral sequencing of larger (42 kDa) proteins [J].
Horn, DM ;
Ge, Y ;
McLafferty, FW .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4778-4784
[10]   Localization of labile posttranslational modifications by electron capture dissociation:: The case of γ-carboxyglutamic acid [J].
Kelleher, RL ;
Zubarev, RA ;
Bush, K ;
Furie, B ;
Furie, BC ;
McLafferty, FW ;
Walsh, CT .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4250-4253