Semicarbazide is a minor thermal decomposition product of azodicarbonamide used in the gaskets of certain food jars

被引:81
作者
Stadler, RH
Mottier, P
Guy, P
Gremaud, E
Varga, N
Lalljie, S
Whitaker, R
Kintscher, J
Dudler, V
Read, WA
Castle, L
机构
[1] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
[2] Unilever Safety & Environm Assurance Ctr, SEAC, Sharnbrook MK44 1LQ, Beds, England
[3] Crown Cork & Seal Corp Technol, Wantage OX12 9BP, Oxon, England
[4] Amcor White Cap Tech Ctr, D-30419 Hannover, Germany
[5] Swiss Fed Off Publ Hlth BAg, Div Food Sci, CH-3003 Bern, Switzerland
[6] Dept Environm Food & Rural Affairs, Cent Sci Lab, York YO41 1LZ, N Yorkshire, England
关键词
D O I
10.1039/b314206j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Evidence is presented for the first time showing that semicarbazide (SEM) is a minor thermal decomposition product of the blowing agent azodicarbonamide ( ADC). A novel direct analytical method based on liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESIMS/MS) has been developed to determine SEM in foamed polyvinyl chloride ( PVC) seals of metal lids, as well as in commercially available ADC. The direct LC-MS/MS method for gaskets entails extraction of the gaskets in hot water, addition of (N-15(2) C-13)-SEM as internal standard, and injection of an aliquot directly into the LC-MS system, achieving good sensitivity (S/N = 348 for 2 ng injected on-column) and monitoring three characteristic mass transitions (m/z 76 --> 31; 76 --> 44; 76 --> 59). Semicarbazide can be detected in thermally treated ADC, reaching up to 0.93 mmol mol(-1) at 220 degreesC, as determined by the direct LC-MS/MS method. This new method is also compared to the classical derivatization method using 2-nitrobenzaldehyde (2-NBA) that is routinely employed to determine SEM as an indicator of the usage of the antimicrobial drug nitrofurazone, the use of which is not authorized in the European Union (EU). Both methods revealed proportional results, with approx. 3-fold higher levels recorded by the direct SEM approach, probably due to differences in the extraction procedures used. A limited survey of plastic seals from used press twist and twist-off metal lids on food jars (non-foamed and foamed) revealed levels of SEM ranging from 2 to 8689 mug kg(-1) (average = 1593 mug kg(-1), n = 57 determinations).
引用
收藏
页码:276 / 281
页数:6
相关论文
共 11 条
[1]   Isolation of bound residues of nitrofuran drugs from tissue by solid-phase extraction with determination by liquid chromatography with UV and tandem mass spectrometric detection [J].
Conneely, A ;
Nugent, A ;
O'Keeffe, M ;
Mulder, PPJ ;
van Rhijn, JA ;
Kovacsics, L ;
Fodor, A ;
McCracken, RJ ;
Kennedy, DG .
ANALYTICA CHIMICA ACTA, 2003, 483 (1-2) :91-98
[2]   Preparation of stable isotope-labeled 2-nitrobenzaldehyde derivatives of four metabolites of nitrofuran antibiotics and their comprehensive characterization by UV, MS, and NMR techniques [J].
Delatour, T ;
Gremaud, E ;
Mottier, P ;
Richoz, J ;
Vera, FA ;
Stadler, RH .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (22) :6371-6379
[3]  
JAAFAR HAS, 1993, CELL POLYM, V12, P303
[4]  
JOINER RR, 1963, CEREAL CHEM, V40, P539
[5]   Determination of the metabolites of nitrofuran antibiotics in animal tissue by high-performance liquid chromatography-tandem mass spectrometry [J].
Leitner, A ;
Zöllner, P ;
Lindner, W .
JOURNAL OF CHROMATOGRAPHY A, 2001, 939 (1-2) :49-58
[6]   HYDRAZINE DERIVATIVES .1. TRANSCARBAMYLATION REACTION [J].
LENOIR, JA ;
WILLIAMS, DF ;
COLEBROO.LD .
CANADIAN JOURNAL OF CHEMISTRY, 1972, 50 (16) :2661-&
[7]  
Lévai G, 1998, ACH-MODELS CHEM, V135, P885
[8]  
*NESTL SOP, 7002 NESTL SOP LCESI
[9]  
PRAKASH AS, 1975, J CHEM SOC P2, V1, P46
[10]   THERMAL-DECOMPOSITION OF BIUREA [J].
RUSSELL, PR ;
STRACHAN, AN .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1978, (04) :323-326