Early mobilization after percutaneous catheterization and vascular closure with a novel device (star-close)

被引:22
作者
Desideri, A [1 ]
Tonello, D
Coscarelli, S
Alitto, F
Daniotti, A
Chioin, R
机构
[1] S Giacomo Hosp, Cardiovasc Res Fdn, Castelfranco Veneto, Italy
[2] S Giacomo Hosp, Cardiac Catheterizat Lab, Castelfranco Veneto, Italy
[3] S Giacomo Hosp, Angiol Unit, Castelfranco Veneto, Italy
关键词
D O I
10.1016/j.amjcard.2005.07.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arteriotomy closure devices used to obtain hemostasis at the end of cardiac catheterization represent a valid alternative to manual compression. We are the first to report on a series of 60 patients in whom a novel system was used, Star-Close, which obtains vessel closure by deployment of a clip at the puncture site. Subsequent early (2 hours) mobilization was obtained in 55 patients (92%). Unsuccessful device deployment occurred in 5 patients. We conclude that Star-Close is a novel arteriotomy closure device that, in selected patients, is safe and allows early deambulation after diagnostic cardiac catheterization. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1408 / 1409
页数:2
相关论文
共 10 条
[1]  
Chamberlin JR, 1999, CATHETER CARDIO INTE, V47, P143, DOI 10.1002/(SICI)1522-726X(199906)47:2<143::AID-CCD1>3.0.CO
[2]  
2-M
[3]   Management of arterial puncture site after catheterization procedures: Evaluating a suture-mediated closure device [J].
Gerckens, U ;
Cattelaens, N ;
Lampe, EG ;
Grube, E .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (12) :1658-1663
[4]   Safety and efficacy of the perclose suture-mediated closure device after diagnostic and interventional catheterizations in a large consecutive population [J].
Kahn, ZM ;
Kumar, M ;
Hollander, G ;
Frankel, R .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (01) :8-13
[5]   RAPID ARTERIAL HEMOSTASIS AND DECREASED ACCESS SITE COMPLICATIONS AFTER CARDIAC-CATHETERIZATION AND ANGIOPLASTY - RESULTS OF A RANDOMIZED TRIAL OF A NOVEL HEMOSTATIC DEVICE [J].
KUSSMAUL, WG ;
BUCHBINDER, M ;
WHITLOW, PL ;
AKER, UT ;
HEUSER, RR ;
KING, SB ;
KENT, KM ;
LEON, MB ;
KOLANSKY, DM ;
SANDZA, JG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) :1685-1692
[6]  
Nasu Kenya, 2003, J Invasive Cardiol, V15, P251
[7]   Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures - A meta-analysis [J].
Nikolsky, E ;
Mehran, R ;
Halkin, A ;
Aymong, ED ;
Mintz, GS ;
Lasic, Z ;
Negoita, M ;
Fahy, M ;
Krieger, S ;
Moussa, I ;
Moses, JW ;
Stone, GW ;
Leon, MB ;
Pocock, SJ ;
Dangas, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) :1200-1209
[8]   COLLAGEN APPLICATION FOR SEALING OF ARTERIAL PUNCTURE SITES IN COMPARISON TO PRESSURE DRESSING - A RANDOMIZED TRIAL [J].
SCHRADER, R ;
STEINBACHER, S ;
BURGER, W ;
KADEL, C ;
VALLBRACHT, C ;
KALTENBACH, M .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 27 (04) :298-302
[9]  
VONHOCH F, 1995, EUR HEART J, V16, P655
[10]   Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angiography [J].
Ward, SR ;
Casale, P ;
Raymond, R ;
Kussmaul, WG ;
Simpfendorfer, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (05) :569-572