Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns

被引:48
作者
Slobodnik, J [1 ]
Oztezkizan, O [1 ]
Lingeman, H [1 ]
Brinkman, UAT [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,NL-1081 HV AMSTERDAM,NETHERLANDS
关键词
environmental analysis; water analysis; adsorbents; sample preparation; pesticides;
D O I
10.1016/0021-9673(96)00472-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 1 samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C-18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (>2 1 for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n=3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 mu g/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10x2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C-18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n=3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C-18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 mu g/l in surface water.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 19 条
[1]   SOLID-PHASE SAMPLE PREPARATION AND STABILITY OF PESTICIDES IN WATER USING EMPORE DISKS [J].
BARCELO, D ;
CHIRON, S ;
LACORTE, S ;
MARTINEZ, E ;
SALAU, JS ;
HENNION, MC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (09) :352-361
[2]   EXTRACTION AND ISOLATION OF TRIAZINE HERBICIDES FROM WATER AND VEGETABLES BY A DOUBLE TRAP TANDEM SYSTEM [J].
BATTISTA, M ;
DICORCIA, A ;
MARCHETTI, M .
ANALYTICAL CHEMISTRY, 1989, 61 (09) :935-939
[3]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF POLAR POLLUTANTS IN SURFACE-WATER USING MEMBRANE EXTRACTION DISKS FOR ONLINE TRACE ENRICHMENT [J].
BROUWER, ER ;
VANIPEREN, DJ ;
LISKA, I ;
LINGEMAN, H ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 47 (04) :257-266
[4]   DETERMINATION OF ACIDIC AND BASIC NEUTRAL PESTICIDES IN WATER WITH A NEW MICROLITER FLOW-RATE LC/MS PARTICLE-BEAM INTERFACE [J].
CAPPIELLO, A ;
FAMIGLINI, G ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1416-1423
[5]   TRACE-LEVEL DETERMINATION OF POLAR PHENOLIC-COMPOUNDS IN AQUEOUS SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ONLINE PRECONCENTRATION ON POROUS GRAPHITIC CARBON [J].
COQUART, V ;
HENNION, MC .
JOURNAL OF CHROMATOGRAPHY, 1992, 600 (02) :195-201
[6]   DETERMINATION OF CHLOROANILINE TRACES IN ENVIRONMENTAL WATERS BY SELECTIVE EXTRACTION WITH 2 TRAPS IN TANDEM AND LIQUID-CHROMATOGRAPHY [J].
DICORCIA, A ;
SAMPERI, R .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1490-1494
[7]  
DICORCIA A, 1994, J AOAC INT, V77, P446
[8]   MULTIRESIDUE METHOD FOR PESTICIDES IN DRINKING-WATER USING A GRAPHITIZED CARBON-BLACK CARTRIDGE EXTRACTION AND LIQUID-CHROMATOGRAPHIC ANALYSIS [J].
DICORCIA, A ;
MARCHETTI, M .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :580-585
[9]   USE OF PYROCARBON SORBENTS FOR TRACE ENRICHMENT OF POLAR COMPOUNDS FROM AQUEOUS SAMPLES WITH ONLINE HPLC ANALYSIS [J].
GOLKIEWICZ, W ;
WERKHOVENGOEWIE, CE ;
BRINKMAN, UAT ;
FREI, RW ;
COLIN, H ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (01) :27-33
[10]  
HENION MC, 1993, J CHROMATOGR, V642, P211