Exergy, exergoeconomic and environmental analyses and evolutionary algorithm based multi-objective optimization of combined cycle power plants

被引:445
作者
Ahmadi, Pouria [1 ]
Dincer, Ibrahim [1 ]
Rosen, Marc A. [1 ]
机构
[1] UOIT, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Optimization; Combined cycle power plant; Exergy; Exergoeconomics; Efficiency; Environmental impact; THERMOECONOMIC ANALYSIS; COMBINED HEAT; ENERGY; SYSTEM; IMPACT;
D O I
10.1016/j.energy.2011.08.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
A comprehensive exergy, exergoeconomic and environmental impact analysis and optimization is reported of several combined cycle power plants (CCPPs). In the first part, thermodynamic analyses based on energy and exergy of the CCPPs are performed, and the effect of supplementary firing on the natural gas-fired CCPP is investigated. The latter step includes the effect of supplementary firing on the performance of bottoming cycle and CO2 emissions, and utilizes the first and second laws of thermodynamics. In the second part, a multi-objective optimization is performed to determine the "best" design parameters, accounting for exergetic, economic and environmental factors. The optimization considers three objective functions: CCPP exergy efficiency, total cost rate of the system products and CO2 emissions of the overall plant. The environmental impact in terms of CO2 emissions is integrated with the exergoeconomic objective function as a new objective function. The results of both exergy and exergoeconomic analyses show that the largest exergy destructions occur in the CCPP combustion chamber, and that increasing the gas turbine inlet temperature decreases the CCPP cost of exergy destruction. The optimization results demonstrates that CO2 emissions are reduced by selecting the best components and using a low fuel injection rate into the combustion chamber. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:5886 / 5898
页数:13
相关论文
共 53 条
[1]  
AHMADI P, 2006, THESIS POWER WATER U
[2]   Energy and exergy analysis of a steam power plant in Jordan [J].
Aijundi, Isam H. .
APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) :324-328
[3]   Exergy analysis of a 420 MW combined cycle power plant [J].
Ameri, M. ;
Ahmadi, P. ;
Khanmohammadi, S. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (02) :175-183
[4]   The study of ambient temperature effects on exergy losses of a heat Recovery Steam Generator [J].
Ameri, Mohammad ;
Ahmadi, Pourya .
CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, :55-+
[5]   Energy, exergy and exergoeconomic analysis of a steam power plant: A case study [J].
Ameri, Mohammad ;
Ahmadi, Pouria ;
Hamidi, Armita .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (05) :499-512
[6]  
[Anonymous], P 2 IR THERM C ISF I
[7]  
[Anonymous], 2007, 3LSEVIER SCI
[8]  
[Anonymous], 1984, Multiple objective optimization with vector evaluated genetic algorithms
[9]  
[Anonymous], P 16 INT C MECH ENG
[10]  
[Anonymous], 2005, INT J EXERGY