Day-to-Day Test-Retest Variability of CBF, CMRO2, and OEF Measurements Using Dynamic 15O PET Studies

被引:54
作者
Bremmer, Jochem P. [2 ]
van Berckel, Bart N. M. [1 ]
Persoon, Suzanne [3 ]
Kappelle, L. Jaap [3 ]
Lammertsma, Adriaan A. [1 ]
Kloet, Reina [1 ]
Luurtsema, Gert [1 ]
Rijbroek, Abraham [1 ,4 ]
Klijn, Catharina J. M. [3 ]
Boellaard, Ronald [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Nucl Med & PET Res, Amsterdam, Netherlands
[2] Univ Med Ctr Utrecht, Dept Neurosurg, Rudolf Magnus Inst Neurosci, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Neurol, Rudolf Magnus Inst Neurosci, Utrecht, Netherlands
[4] Kennemer Gasthuis, Dept Surg, Haarlem, Netherlands
关键词
Parametric; CBF; CMRO2; OEF; PET; POSITRON-EMISSION-TOMOGRAPHY; CEREBRAL-BLOOD-FLOW; REGIONAL OXYGEN EXTRACTION; CONTINUOUS INHALATION; QUANTITATIVE MEASUREMENT; ERROR ANALYSIS; NORMAL VALUES; HUMAN BRAIN; WATER; VALIDATION;
D O I
10.1007/s11307-010-0382-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We assessed test-retest variability of cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO2), and oxygen extraction fraction (OEF) measurements derived from dynamic O-15 positron emission tomography (PET) scans. In seven healthy volunteers, complete test-retest O-15 PET studies were obtained; test-retest variability and left-to-right ratios of CBF, CBV, OEF, and CMRO2 in arterial flow territories were calculated. Whole-brain test-retest coefficients of variation for CBF, CBV, CMRO2, and OEF were 8.8%, 13.8%, 5.3%, and 9.3%, respectively. Test-retest variability of CBV left-to-right ratios was < 7.4% across all territories. Corresponding values for CBF, CMRO2, and OEF were better, i.e., < 4.5%, < 4.0%, and < 1.4%, respectively. The test-retest variability of CMRO2 measurements derived from dynamic O-15 PET scans is comparable to within-session test-retest variability derived from steady-state O-15 PET scans. Excellent regional test-retest variability was observed for CBF, CMRO2, and OEF. Variability of absolute CBF and OEF measurements is probably affected by physiological day-to-day variability of CBF.
引用
收藏
页码:759 / 768
页数:10
相关论文
共 37 条
[1]   STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY [J].
ALPERT, NM ;
ERIKSSON, L ;
CHANG, JY ;
BERGSTROM, M ;
LITTON, JE ;
CORREIA, JA ;
BOHM, C ;
ACKERMAN, RH ;
TAVERAS, JM .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) :28-34
[2]   Evaluation of basis function and linear least squares methods for generating parametric blood flow images using 15O-water and positron emission tomography [J].
Boellaard, R ;
Knaapen, P ;
Rijbroek, A ;
Luurtsema, GJJ ;
Lammertsma, AA .
MOLECULAR IMAGING AND BIOLOGY, 2005, 7 (04) :273-285
[3]   Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET [J].
Boellaard, R ;
van Lingen, A ;
van Balen, SCM ;
Hoving, BG ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :81-89
[4]  
BOELLAARD R, 2007, J CEREB BLOOD FLOW M, V27, pS1
[5]  
Brix G, 1997, J NUCL MED, V38, P1614
[6]   Intersubject variability and reproducibility of 15O PET studies [J].
Coles, JP ;
Fryer, TD ;
Bradley, PG ;
Nortje, J ;
Smielewski, P ;
Rice, K ;
Clark, JC ;
Pickard, JD ;
Menon, DK .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2006, 26 (01) :48-57
[7]   Dietary caffeine consumption and withdrawal: Confounding variables in quantitative cerebral perfusion studies? [J].
Field, AS ;
Laurienti, PJ ;
Yen, YF ;
Burdette, JH ;
Moody, DM .
RADIOLOGY, 2003, 227 (01) :129-135
[8]   QUANTITATIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN-METABOLISM IN MAN USING O-15 AND POSITRON EMISSION TOMOGRAPHY - THEORY, PROCEDURE, AND NORMAL VALUES [J].
FRACKOWIAK, RSJ ;
LENZI, GL ;
JONES, T ;
HEATHER, JD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) :727-736
[9]   Importance of hemodynamic factors in the prognosis of symptomatic carotid occlusion [J].
Grubb, RL ;
Derdeyn, CP ;
Fritsch, SM ;
Carpenter, DA ;
Yundt, KD ;
Videen, TO ;
Spitznagel, EL ;
Powers, WJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (12) :1055-1060
[10]  
Hattori N, 2004, J NUCL MED, V45, P765