Control of a three-phase PWM rectifier using estimated ac-side and dc-side voltages

被引:40
作者
Ohnuki, T [1 ]
Miyashita, O
Lataire, P
Maggetto, G
机构
[1] Tokyo Denki Univ, Dept Appl Electron Engn, Hatoyama, Saitama 35003, Japan
[2] Free Univ Brussels, Brussels, Belgium
关键词
AC-voltage sensorless control; dc-voltage sensorless control; high power factor; PWM rectifier;
D O I
10.1109/63.750174
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new control method of a pulsewidth modulation (PWM) rectifier without measuring ac- and de-side voltages is proposed. rls information about these voltages is necessary for the controller, all required voltage values are estimated from the measured line currents and the calculated values of the input reactor voltage during switching of the rectifier circuit. The input reactor voltage can be obtained by using a differentiator that produces the derivative of the Line current or by detecting the voltage induced in a secondary winding wound on the input reactor, The secondary winding creates the electric isolation between the main circuit and the controller, The proposed method is verified bg experiment. This paper describes the estimation method, gives the configuration of the controller, and discusses steady-state and transient performances of the rectifier.
引用
收藏
页码:222 / 226
页数:5
相关论文
共 6 条
[1]   High power factor PWM rectifiers with an analog pulsewidth prediction controller [J].
Ohnuki, T ;
Miyashita, O ;
Haneyoshi, T ;
Ohtsuji, E .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (03) :460-465
[2]  
OHNUKI T, P EPE 97, V2, P881
[3]  
OHNUKI T, P EPE 95, V3, P33
[4]  
Ohtsuji E., 1997, Transactions of the Institute of Electrical Engineers of Japan, Part D, V117-D, P44, DOI 10.1541/ieejias.117.44
[5]  
SMIDT PJM, P EPE 95, V3, P275
[6]  
Takeshita T., 1994, Transactions of the Institute of Electrical Engineers of Japan, Part D, V114-D, P1211, DOI 10.1541/ieejias.114.1211